{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2003-1603 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2003-1603 yet. Limit exposure of the affected software until one is available.","what":"CVE-2003-1603 is a critical vulnerability in n/a, published on 4 Aug 2015. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2003-1603 and fix it if it is affected.\n\nWhat it is: CVE-2003-1603 is a critical vulnerability in n/a, published on 4 Aug 2015. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2003-1603 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2003-1603/ (Markdown: https://insights.sbomify.com/CVE-2003-1603/index.md)","id":"CVE-2003-1603","markdown":"https://insights.sbomify.com/CVE-2003-1603/index.md","name":"CVE-2003-1603","record":{"aliases":["GHSA-cxq8-frpg-8q64"],"analysis":{"component_type":"iot_embedded","fix_type":"configuration_change","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical imaging device","requires_auth":"none","summary":"Attackers can access GE Healthcare Discovery VH devices using default passwords for FTP and Interfile services, potentially compromising data.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"discovery_vh","vendor":"gehealthcare"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-255","name":null}],"description":"GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) \"2\" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in n/a","id":"CVE-2003-1603","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2003"},"n_packages":0,"n_references":4,"next":{"headline":"The redirect_target function in net/ipv4/netfilter/ipt_REDIRECT.c in the Linux kernel before 2.6.0 allows remote attackers to cause a denial","id":"CVE-2003-1604"},"packages":[],"prev":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2003-1602"},"products":["n/a"],"published":"2015-08-04","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-08","vendors":["n/a"]},"summary":"Attackers can access GE Healthcare Discovery VH devices using default passwords for FTP and Interfile services, potentially compromising data.","url":"https://insights.sbomify.com/CVE-2003-1603/"}