{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2006-2316 exists.","fix":"No fix has been published for CVE-2006-2316 yet. Limit exposure of the affected software until one is available.","what":"CVE-2006-2316 is a medium-severity vulnerability in n/a, published on 12 May 2006. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2006-2316 and fix it if it is affected.\n\nWhat it is: CVE-2006-2316 is a medium-severity vulnerability in n/a, published on 12 May 2006. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2006-2316 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2006-2316/ (Markdown: https://insights.sbomify.com/CVE-2006-2316/index.md)","id":"CVE-2006-2316","markdown":"https://insights.sbomify.com/CVE-2006-2316/index.md","name":"CVE-2006-2316","record":{"aliases":["GHSA-4rxf-v7cf-f539"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["data_read","data_modify","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Intel PROset Wireless","requires_auth":"low_privilege","summary":"Local attackers can read or modify sensitive data and cause denial of service due to weak permissions on a shared memory section in Intel PROset/Wireless software.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"proset_wireless","vendor":"intel"}],"cvss":{"score":4.9,"severity":"medium","source":"nvd","vector":"AV:L/AC:L/Au:N/C:C/I:N/A:N","version":"2.0"},"cwes":[],"description":"S24EvMon.exe in the Intel PROset/Wireless software, possibly 10.1.0.33, uses a S24EventManagerSharedMemory shared memory section with weak permissions, which allows local users to read or modify passwords or other data, or cause a denial of service.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2006-05-09","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2006-05-09","kind":"exploitdb","ref":"1772","stars":null,"title":"Intel Wireless Service - 's24evmon.exe' Shared Memory"}],"tier":"weaponised"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2006-2316","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2006"},"n_packages":0,"n_references":8,"next":{"headline":"Path traversal in n/a","id":"CVE-2006-2317"},"packages":[],"prev":{"headline":"Code injection in n/a","id":"CVE-2006-2315"},"products":["n/a"],"published":"2006-05-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-07","vendors":["n/a"]},"summary":"Local attackers can read or modify sensitive data and cause denial of service due to weak permissions on a shared memory section in Intel PROset/Wireless software.","url":"https://insights.sbomify.com/CVE-2006-2316/"}