{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2006-2704 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2006-2704 yet. Limit exposure of the affected software until one is available.","what":"CVE-2006-2704 is a medium-severity vulnerability in n/a, published on 31 May 2006. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2006-2704 and fix it if it is affected.\n\nWhat it is: CVE-2006-2704 is a medium-severity vulnerability in n/a, published on 31 May 2006. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2006-2704 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2006-2704/ (Markdown: https://insights.sbomify.com/CVE-2006-2704/index.md)","id":"CVE-2006-2704","markdown":"https://insights.sbomify.com/CVE-2006-2704/index.md","name":"CVE-2006-2704","record":{"aliases":["GHSA-m543-w5cq-4vwh"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Secure Elements Class 5","requires_auth":"none","summary":"Remote attackers can read sensitive information because the Secure Elements Class 5 AVR server and client transmit messages in cleartext.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"c5_enterprise_vulnerability_management","vendor":"secure_elements"}],"cvss":{"score":5,"severity":"medium","source":"nvd","vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","version":"2.0"},"cwes":[],"description":"Secure Elements Class 5 AVR server and client (aka C5 EVM) before 2.8.1 send messages in cleartext, which allows remote attackers to read sensitive vulnerability information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2006-2704","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2006"},"n_packages":0,"n_references":8,"next":{"headline":"Denial of service in n/a","id":"CVE-2006-2705"},"packages":[],"prev":{"headline":"Weak cryptography in n/a","id":"CVE-2006-2703"},"products":["n/a"],"published":"2006-05-31","related":[{"cvss_score":7.5,"headline":"Missing authorization in n/a","id":"CVE-2006-2715","kev_date_added":null,"published":"2006-05-31"},{"cvss_score":7.5,"headline":"Hardcoded credentials in n/a","id":"CVE-2006-2716","kev_date_added":null,"published":"2006-05-31"},{"cvss_score":5,"headline":"Denial of service in n/a","id":"CVE-2006-2705","kev_date_added":null,"published":"2006-05-31"},{"cvss_score":5,"headline":"Information disclosure in n/a","id":"CVE-2006-2713","kev_date_added":null,"published":"2006-05-31"},{"cvss_score":5,"headline":"Missing authorization in n/a","id":"CVE-2006-2714","kev_date_added":null,"published":"2006-05-31"},{"cvss_score":4,"headline":"Path traversal in n/a","id":"CVE-2006-2717","kev_date_added":null,"published":"2006-05-31"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-07","vendors":["n/a"]},"summary":"Remote attackers can read sensitive information because the Secure Elements Class 5 AVR server and client transmit messages in cleartext.","url":"https://insights.sbomify.com/CVE-2006-2704/"}