{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2009-1555 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2009-1555 yet. Limit exposure of the affected software until one is available.","what":"CVE-2009-1555 is a medium-severity vulnerability in n/a, published on 6 May 2009. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2009-1555 and fix it if it is affected.\n\nWhat it is: CVE-2009-1555 is a medium-severity vulnerability in n/a, published on 6 May 2009. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2009-1555 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2009-1555/ (Markdown: https://insights.sbomify.com/CVE-2009-1555/index.md)","id":"CVE-2009-1555","markdown":"https://insights.sbomify.com/CVE-2009-1555/index.md","name":"CVE-2009-1555","record":{"aliases":["GHSA-77hj-fg3w-jpff"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"wireless video camera","requires_auth":"none","summary":"Remote attackers can obtain sensitive configuration data, including passwords, by reading process memory via a Setup Wizard command.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"wvc54gca","vendor":"cisco"}],"cvss":{"score":5,"severity":"medium","source":"nvd","vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","version":"2.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 sends configuration data in response to a Setup Wizard remote-management command, which allows remote attackers to obtain sensitive information such as passwords by reading the SetupWizard.exe process memory, a related issue to CVE-2008-4390.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2009-1555","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2009"},"n_packages":0,"n_references":4,"next":{"headline":"Path traversal in n/a","id":"CVE-2009-1556"},"packages":[],"prev":{"headline":"Cross-site scripting in n/a","id":"CVE-2009-1554"},"products":["n/a"],"published":"2009-05-06","related":[{"cvss_score":7.8,"headline":"Path traversal in n/a","id":"CVE-2009-1558","kev_date_added":null,"published":"2009-05-06"},{"cvss_score":7.8,"headline":"Path traversal in n/a","id":"CVE-2009-1559","kev_date_added":null,"published":"2009-05-06"},{"cvss_score":4.3,"headline":"Cross-site scripting in n/a","id":"CVE-2009-1557","kev_date_added":null,"published":"2009-05-06"},{"cvss_score":3.5,"headline":"Path traversal in n/a","id":"CVE-2009-1556","kev_date_added":null,"published":"2009-05-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-07","vendors":["n/a"]},"summary":"Remote attackers can obtain sensitive configuration data, including passwords, by reading process memory via a Setup Wizard command.","url":"https://insights.sbomify.com/CVE-2009-1555/"}