{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2010-4733 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2010-4733 yet. Limit exposure of the affected software until one is available.","what":"CVE-2010-4733 is a critical vulnerability in n/a, published on 14 Feb 2011. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2010-4733 and fix it if it is affected.\n\nWhat it is: CVE-2010-4733 is a critical vulnerability in n/a, published on 14 Feb 2011. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2010-4733 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2010-4733/ (Markdown: https://insights.sbomify.com/CVE-2010-4733/index.md)","id":"CVE-2010-4733","markdown":"https://insights.sbomify.com/CVE-2010-4733/index.md","name":"CVE-2010-4733","record":{"aliases":["GHSA-gv4m-989j-rw5p"],"analysis":{"component_type":"ics_ot","fix_type":"configuration_change","impacts":["privilege_escalation","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial SCADA Gateway","requires_auth":"none","summary":"Remote attackers can gain superadmin access to NetBiter SCADA devices using default credentials exposed via the web interface.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"netbiter_easyconnect_ec150","vendor":"intellicom"},{"product":"netbiter_modbus_rtu-tcp_gateway_mb100","vendor":"intellicom"},{"product":"netbiter_nb100","vendor":"intellicom"},{"product":"netbiter_nb200","vendor":"intellicom"},{"product":"netbiter_serial_ethernet_server_ss100","vendor":"intellicom"},{"product":"netbiter_webscada_ws100","vendor":"intellicom"},{"product":"netbiter_webscada_ws200","vendor":"intellicom"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-255","name":null}],"description":"WebSCADA WS100 and WS200, Easy Connect EC150, Modbus RTU - TCP Gateway MB100, and Serial Ethernet Server SS100 on the IntelliCom NetBiter NB100 and NB200 platforms have a default username and password, which makes it easier for remote attackers to obtain superadmin access via the web interface, a different vulnerability than CVE-2009-4463.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in n/a","id":"CVE-2010-4733","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2010"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2010-4734"},"packages":[],"prev":{"headline":"Code injection in n/a","id":"CVE-2010-4732"},"products":["n/a"],"published":"2011-02-14","related":[{"cvss_score":9,"headline":"Code injection in n/a","id":"CVE-2010-4732","kev_date_added":null,"published":"2011-02-14"},{"cvss_score":6.8,"headline":"Path traversal in n/a","id":"CVE-2010-4730","kev_date_added":null,"published":"2011-02-14"},{"cvss_score":6.8,"headline":"Path traversal in n/a","id":"CVE-2010-4731","kev_date_added":null,"published":"2011-02-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["n/a"]},"summary":"Remote attackers can gain superadmin access to NetBiter SCADA devices using default credentials exposed via the web interface.","url":"https://insights.sbomify.com/CVE-2010-4733/"}