{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2010-5306 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2010-5306 yet. Limit exposure of the affected software until one is available.","what":"CVE-2010-5306 is a critical vulnerability in n/a, published on 4 Aug 2015."},"fix_prompt":"Check this codebase for CVE-2010-5306 and fix it if it is affected.\n\nWhat it is: CVE-2010-5306 is a critical vulnerability in n/a, published on 4 Aug 2015. \nExploitation: There is no known exploitation of CVE-2010-5306 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2010-5306/ (Markdown: https://insights.sbomify.com/CVE-2010-5306/index.md)","id":"CVE-2010-5306","markdown":"https://insights.sbomify.com/CVE-2010-5306/index.md","name":"CVE-2010-5306","record":{"aliases":["GHSA-jc3h-vhq8-h93h"],"analysis":{"component_type":"iot_embedded","fix_type":"configuration_change","impacts":["privilege_escalation","code_execution"],"network_reachable":"unknown","non_default_config":false,"product_category":"Medical CT Scanner","requires_auth":"none","summary":"Attackers can gain root access to GE Healthcare CT scanners using a hardcoded default password, potentially compromising device integrity and patient data.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"optima_ct520_firmware","vendor":"gehealthcare"},{"product":"optima_ct540_firmware","vendor":"gehealthcare"},{"product":"optima_ct680_firmware","vendor":"gehealthcare"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-255","name":null}],"description":"GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in n/a","id":"CVE-2010-5306","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2010"},"n_packages":0,"n_references":6,"next":{"headline":"Hardcoded credentials in n/a","id":"CVE-2010-5307"},"packages":[],"prev":{"headline":"Rockwell PLC5/SLC5/0x/RSLogix Credentials management","id":"CVE-2010-5305"},"products":["n/a"],"published":"2015-08-04","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-07","vendors":["n/a"]},"summary":"Attackers can gain root access to GE Healthcare CT scanners using a hardcoded default password, potentially compromising device integrity and patient data.","url":"https://insights.sbomify.com/CVE-2010-5306/"}