{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2011-2963 exists.","fix":"No fix has been published for CVE-2011-2963 yet. Limit exposure of the affected software until one is available.","what":"CVE-2011-2963 is a critical authentication bypass vulnerability in n/a, published on 29 Jul 2011. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2011-2963 and fix it if it is affected.\n\nWhat it is: CVE-2011-2963 is a critical authentication bypass vulnerability in n/a, published on 29 Jul 2011. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2011-2963 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2011-2963/ (Markdown: https://insights.sbomify.com/CVE-2011-2963/index.md)","id":"CVE-2011-2963","markdown":"https://insights.sbomify.com/CVE-2011-2963/index.md","name":"CVE-2011-2963","record":{"aliases":["GHSA-xxpf-83g5-3w2v"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution","data_read","data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA HMI software","requires_auth":"none","summary":"Remote attackers can bypass authentication to execute code, read or delete data, and cause denial of service in Progea Movicon SCADA software.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"movicon","vendor":"progea"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"TCPUploadServer.exe in Progea Movicon 11.2 before Build 1084 does not require authentication for critical functions, which allows remote attackers to obtain sensitive information, delete files, execute arbitrary programs, or cause a denial of service (crash) via a crafted packet to TCP port 10651.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2011-03-23","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2011-03-23","kind":"exploitdb","ref":"17034","stars":null,"title":"Progea Movicon 11 - 'TCPUploadServer' Remote File System"}],"tier":"weaponised"},"has_fix":null,"headline":"Auth bypass in n/a","id":"CVE-2011-2963","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2011"},"n_packages":0,"n_references":5,"next":{"headline":"Code injection in n/a","id":"CVE-2011-2964"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2011-2962"},"products":["n/a"],"published":"2011-07-29","related":[{"cvss_score":7.8,"headline":"Other in Progea Movicon SCADA/HMI","id":"CVE-2017-14017","kev_date_added":null,"published":"2017-10-19"},{"cvss_score":7.8,"headline":"Memory corruption in n/a","id":"CVE-2012-1804","kev_date_added":null,"published":"2012-05-14"},{"cvss_score":6.7,"headline":"Privilege escalation in Progea Movicon SCADA/HMI","id":"CVE-2017-14019","kev_date_added":null,"published":"2017-10-19"},{"cvss_score":4.3,"headline":"Progea Movicon SCADA Exposure of Sensitive Information to an Unauthorized Actor","id":"CVE-2014-0778","kev_date_added":null,"published":"2014-04-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["n/a"]},"summary":"Remote attackers can bypass authentication to execute code, read or delete data, and cause denial of service in Progea Movicon SCADA software.","url":"https://insights.sbomify.com/CVE-2011-2963/"}