{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2011-3499 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2011-3499 yet. Limit exposure of the affected software until one is available.","what":"CVE-2011-3499 is a critical memory corruption vulnerability in n/a, published on 16 Sep 2011. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2011-3499 and fix it if it is affected.\n\nWhat it is: CVE-2011-3499 is a critical memory corruption vulnerability in n/a, published on 16 Sep 2011. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2011-3499 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2011-3499/ (Markdown: https://insights.sbomify.com/CVE-2011-3499/index.md)","id":"CVE-2011-3499","markdown":"https://insights.sbomify.com/CVE-2011-3499/index.md","name":"CVE-2011-3499","record":{"aliases":["GHSA-qm8f-5cf9-f84f"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"HMI SCADA software","requires_auth":"none","summary":"Remote attackers can cause denial of service or execute arbitrary code via a crafted EIDP packet in Progea Movicon/PowerHMI.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"movicon_powerhmi","vendor":"progea"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"Progea Movicon / PowerHMI 11.2.1085 and earlier allows remote attackers to cause a denial of service (memory corruption and crash) and possibly execute arbitrary code via an EIDP packet with a large size field, which writes a zero byte to an arbitrary memory location.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2011-09-14","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2011-09-14","kind":"exploitdb","ref":"17842","stars":null,"title":"progea movicon / powerhmi 11.2.1085 - Multiple Vulnerabilities"}],"tier":"poc_unverified"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2011-3499","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2011"},"n_packages":0,"n_references":3,"next":{"headline":"Path traversal in n/a","id":"CVE-2011-3500"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2011-3498"},"products":["n/a"],"published":"2011-09-16","related":[{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2011-3491","kev_date_added":null,"published":"2011-09-16"},{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2011-3498","kev_date_added":null,"published":"2011-09-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Remote attackers can cause denial of service or execute arbitrary code via a crafted EIDP packet in Progea Movicon/PowerHMI.","url":"https://insights.sbomify.com/CVE-2011-3499/"}