{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2012-1812 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2012-1812 yet. Limit exposure of the affected software until one is available.","what":"CVE-2012-1812 is a medium-severity vulnerability in n/a, published on 13 Nov 2012. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2012-1812 and fix it if it is affected.\n\nWhat it is: CVE-2012-1812 is a medium-severity vulnerability in n/a, published on 13 Nov 2012. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2012-1812 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2012-1812/ (Markdown: https://insights.sbomify.com/CVE-2012-1812/index.md)","id":"CVE-2012-1812","markdown":"https://insights.sbomify.com/CVE-2012-1812/index.md","name":"CVE-2012-1812","record":{"aliases":["GHSA-3p28-g7gh-66v2"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA system","requires_auth":"none","summary":"Remote attackers can obtain sensitive cleartext information from the C3-ilex EOScada failover service via TCP port 12000.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"certcc","cpe":[{"product":"eoscada","vendor":"c3-ilex"}],"cvss":{"score":5,"severity":"medium","source":"nvd","vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","version":"2.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"eosfailoverservice.exe in C3-ilex EOScada before 11.0.19.2 allows remote attackers to obtain sensitive cleartext information via a session on TCP port 12000.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2012-1812","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2012"},"n_packages":0,"n_references":4,"next":{"headline":"Denial of service in n/a","id":"CVE-2012-1813"},"packages":[],"prev":{"headline":"Denial of service in n/a","id":"CVE-2012-1811"},"products":["n/a"],"published":"2012-11-13","related":[{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2012-1811","kev_date_added":null,"published":"2012-11-13"},{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2012-1813","kev_date_added":null,"published":"2012-11-13"},{"cvss_score":5,"headline":"Denial of service in n/a","id":"CVE-2012-1810","kev_date_added":null,"published":"2012-11-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Remote attackers can obtain sensitive cleartext information from the C3-ilex EOScada failover service via TCP port 12000.","url":"https://insights.sbomify.com/CVE-2012-1812/"}