{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2012-2598 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2012-2598 yet. Limit exposure of the affected software until one is available.","what":"CVE-2012-2598 is a medium-severity memory corruption vulnerability in n/a, published on 8 Jun 2012. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2012-2598 and fix it if it is affected.\n\nWhat it is: CVE-2012-2598 is a medium-severity memory corruption vulnerability in n/a, published on 8 Jun 2012. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2012-2598 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2012-2598/ (Markdown: https://insights.sbomify.com/CVE-2012-2598/index.md)","id":"CVE-2012-2598","markdown":"https://insights.sbomify.com/CVE-2012-2598/index.md","name":"CVE-2012-2598","record":{"aliases":["GHSA-w3p4-49wh-m79f"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA HMI software","requires_auth":"none","summary":"Remote attackers can cause a denial of service in Siemens WinCC via crafted input to the DiagAgent web server.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"certcc","cpe":[{"product":"wincc","vendor":"siemens"}],"cvss":{"score":4.3,"severity":"medium","source":"nvd","vector":"AV:N/AC:M/Au:N/C:N/I:N/A:P","version":"2.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2012-2598","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2012"},"n_packages":0,"n_references":2,"next":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2012-2599"},"packages":[],"prev":{"headline":"Path traversal in n/a","id":"CVE-2012-2597"},"products":["n/a"],"published":"2012-06-08","related":[{"cvss_score":7.8,"headline":"Privilege escalation in SIMATIC WinCC","id":"CVE-2023-30897","kev_date_added":null,"published":"2023-06-13"},{"cvss_score":6.8,"headline":"Auth bypass in n/a","id":"CVE-2015-2823","kev_date_added":null,"published":"2015-04-08"},{"cvss_score":6.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2013-4911","kev_date_added":null,"published":"2013-07-31"},{"cvss_score":5.8,"headline":"Open redirect in n/a","id":"CVE-2013-4912","kev_date_added":null,"published":"2013-07-31"},{"cvss_score":5.8,"headline":"Open redirect in n/a","id":"CVE-2012-3003","kev_date_added":null,"published":"2012-06-08"},{"cvss_score":5.5,"headline":"Code injection in n/a","id":"CVE-2012-2596","kev_date_added":null,"published":"2012-06-08"},{"cvss_score":5,"headline":"Weak cryptography in n/a","id":"CVE-2015-1358","kev_date_added":null,"published":"2015-02-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["n/a"]},"summary":"Remote attackers can cause a denial of service in Siemens WinCC via crafted input to the DiagAgent web server.","url":"https://insights.sbomify.com/CVE-2012-2598/"}