{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2012-2990 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2012-2990 yet. Limit exposure of the affected software until one is available.","what":"CVE-2012-2990 is a critical code injection vulnerability in n/a, published on 24 Aug 2012. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2012-2990 and fix it if it is affected.\n\nWhat it is: CVE-2012-2990 is a critical code injection vulnerability in n/a, published on 24 Aug 2012. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2012-2990 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2012-2990/ (Markdown: https://insights.sbomify.com/CVE-2012-2990/index.md)","id":"CVE-2012-2990","markdown":"https://insights.sbomify.com/CVE-2012-2990/index.md","name":"CVE-2012-2990","record":{"aliases":["GHSA-6ff5-xppw-fx3m"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Samsung KIES","requires_auth":"none","summary":"Remote attackers can execute arbitrary code on client machines via a crafted HTML document exploiting the MASetupCaller ActiveX control in Samsung KIES.","user_interaction":"required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"certcc","cpe":[{"product":"kies","vendor":"samsung"}],"cvss":{"score":9.3,"severity":"critical","source":"nvd","vector":"AV:N/AC:M/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"}],"description":"The MASetupCaller ActiveX control before 1.4.2012.508 in MASetupCaller.dll in MarkAny ContentSAFER, as distributed in Samsung KIES before 2.3.2.12074_13_13, does not properly implement unspecified methods, which allows remote attackers to download an arbitrary program onto a client machine, and execute this program, via a crafted HTML document.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in n/a","id":"CVE-2012-2990","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2012"},"n_packages":0,"n_references":2,"next":{"headline":"Business logic in n/a","id":"CVE-2012-2991"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2012-2986"},"products":["n/a"],"published":"2012-08-24","related":[{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2012-6429","kev_date_added":null,"published":"2014-04-04"},{"cvss_score":9.8,"headline":"Code injection in n/a","id":"CVE-2012-3807","kev_date_added":null,"published":"2020-01-09"},{"cvss_score":7.5,"headline":"Null dereference in n/a","id":"CVE-2012-3806","kev_date_added":null,"published":"2020-01-09"},{"cvss_score":7.5,"headline":"Path traversal in n/a","id":"CVE-2012-3808","kev_date_added":null,"published":"2020-01-09"},{"cvss_score":7.5,"headline":"Path traversal in n/a","id":"CVE-2012-3809","kev_date_added":null,"published":"2020-01-09"},{"cvss_score":7.5,"headline":"Other in n/a","id":"CVE-2012-3810","kev_date_added":null,"published":"2020-01-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["n/a"]},"summary":"Remote attackers can execute arbitrary code on client machines via a crafted HTML document exploiting the MASetupCaller ActiveX control in Samsung KIES.","url":"https://insights.sbomify.com/CVE-2012-2990/"}