{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2012-4026 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2012-4026 yet. Limit exposure of the affected software until one is available.","what":"CVE-2012-4026 is a medium-severity denial of service vulnerability in n/a, published on 16 Jul 2012. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2012-4026 and fix it if it is affected.\n\nWhat it is: CVE-2012-4026 is a medium-severity denial of service vulnerability in n/a, published on 16 Jul 2012. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2012-4026 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2012-4026/ (Markdown: https://insights.sbomify.com/CVE-2012-4026/index.md)","id":"CVE-2012-4026","markdown":"https://insights.sbomify.com/CVE-2012-4026/index.md","name":"CVE-2012-4026","record":{"aliases":["GHSA-2r6j-phhp-ffw3"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Building automation server","requires_auth":"none","summary":"Remote attackers can trigger false alerts in Johnson Controls Pegasys P2000 servers by sending crafted packets to the upload port.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"pegasys_p2000_server","vendor":"johnsoncontrols"},{"product":"pegasys_p2000_server_software","vendor":"johnsoncontrols"}],"cvss":{"score":5,"severity":"medium","source":"nvd","vector":"AV:N/AC:L/Au:N/C:N/I:P/A:N","version":"2.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"The Johnson Controls Pegasys P2000 server with software before 3.11 allows remote attackers to trigger false alerts via crafted packets to TCP port 41013 (aka the upload port), a different vulnerability than CVE-2012-2607.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in n/a","id":"CVE-2012-4026","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2012"},"n_packages":0,"n_references":2,"next":{"headline":"Path traversal in n/a","id":"CVE-2012-4027"},"packages":[],"prev":{"headline":"Integer overflow in n/a","id":"CVE-2012-4025"},"products":["n/a"],"published":"2012-07-16","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["n/a"]},"summary":"Remote attackers can trigger false alerts in Johnson Controls Pegasys P2000 servers by sending crafted packets to the upload port.","url":"https://insights.sbomify.com/CVE-2012-4026/"}