{"answers":{"affected":"It affects 2 products.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2012-4357 exists.","fix":"No fix has been published for CVE-2012-4357 yet. Limit exposure of the affected software until one is available.","what":"CVE-2012-4357 is a critical memory corruption vulnerability in n/a, published on 19 Aug 2012. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2012-4357 and fix it if it is affected.\n\nWhat it is: CVE-2012-4357 is a critical memory corruption vulnerability in n/a, published on 19 Aug 2012. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2012-4357 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2012-4357/ (Markdown: https://insights.sbomify.com/CVE-2012-4357/index.md)","id":"CVE-2012-4357","markdown":"https://insights.sbomify.com/CVE-2012-4357/index.md","name":"CVE-2012-4357","record":{"aliases":["GHSA-gmjm-f66f-wrq7"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA software","requires_auth":"none","summary":"Remote attackers can execute arbitrary code on Sielco Sistemi Winlog SCADA systems by sending a malicious TCP packet with an invalid file-pointer index.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"winlog_lite","vendor":"sielcosistemi"},{"product":"winlog_pro","vendor":"sielcosistemi"}],"cvss":{"score":9.3,"severity":"critical","source":"nvd","vector":"AV:N/AC:M/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"Array index error in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 might allow remote attackers to execute arbitrary code by referencing, within a port-46824 TCP packet, an invalid file-pointer index that leads to execution of an EnterCriticalSection code block.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2012-06-27","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2012-06-27","kind":"exploitdb","ref":"19409","stars":null,"title":"Sielco Sistemi Winlog 2.07.16 - Multiple Vulnerabilities"}],"tier":"weaponised"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2012-4357","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2012"},"n_packages":0,"n_references":4,"next":{"headline":"Denial of service in n/a","id":"CVE-2012-4358"},"packages":[],"prev":{"headline":"Path traversal in n/a","id":"CVE-2012-4356"},"products":["n/a"],"published":"2012-08-19","related":[{"cvss_score":9.3,"headline":"Memory corruption in n/a","id":"CVE-2012-4353","kev_date_added":null,"published":"2012-08-19"},{"cvss_score":9.3,"headline":"Memory corruption in n/a","id":"CVE-2012-4354","kev_date_added":null,"published":"2012-08-19"},{"cvss_score":9.3,"headline":"Integer overflow in n/a","id":"CVE-2012-4355","kev_date_added":null,"published":"2012-08-19"},{"cvss_score":9.3,"headline":"Denial of service in n/a","id":"CVE-2012-4358","kev_date_added":null,"published":"2012-08-19"},{"cvss_score":9.3,"headline":"Integer overflow in n/a","id":"CVE-2012-4359","kev_date_added":null,"published":"2012-08-19"},{"cvss_score":9.3,"headline":"Memory corruption in n/a","id":"CVE-2012-3815","kev_date_added":null,"published":"2012-06-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["n/a"]},"summary":"Remote attackers can execute arbitrary code on Sielco Sistemi Winlog SCADA systems by sending a malicious TCP packet with an invalid file-pointer index.","url":"https://insights.sbomify.com/CVE-2012-4357/"}