{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2012-5864 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2012-5864 yet. Limit exposure of the affected software until one is available.","what":"CVE-2012-5864 is a critical missing authorization vulnerability in Sinapsi eSolar, published on 23 Nov 2012. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2012-5864 and fix it if it is affected.\n\nWhat it is: CVE-2012-5864 is a critical missing authorization vulnerability in Sinapsi eSolar, published on 23 Nov 2012. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2012-5864 in the wild and no public exploit code.\n\nAffected product: Sinapsi eSolar. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2012-5864/ (Markdown: https://insights.sbomify.com/CVE-2012-5864/index.md)","id":"CVE-2012-5864","markdown":"https://insights.sbomify.com/CVE-2012-5864/index.md","name":"CVE-2012-5864","record":{"aliases":["GHSA-v26h-2hg9-6mq7"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["privilege_escalation","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Sinapsi eSolar device","requires_auth":"none","summary":"Attackers can gain unauthorized administrative access to Sinapsi eSolar devices by directly visiting internal pages without authentication.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"esolar_duo_photovoltaic_system_monitor","vendor":"sinapsitech"},{"product":"esolar_light_photovoltaic_system_monitor","vendor":"sinapsitech"},{"product":"esolar_photovoltaic_system_monitor","vendor":"sinapsitech"},{"product":"sinapsi_firmware","vendor":"sinapsitech"}],"cvss":{"score":9.4,"severity":"critical","source":"cna","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:N","version":"2.0"},"cwes":[{"id":"CWE-264","name":null},{"id":"CWE-287","name":"Improper Authentication"}],"description":"These Sinapsi devices \ndo not check if users that visit pages within the device have properly \nauthenticated. By directly visiting the pages within the device, \nattackers can gain unauthorized access with administrative privileges.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2012-09-12","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2012-09-12","kind":"exploitdb","ref":"21273","stars":null,"title":"Ezylog Photovoltaic Management Server - Multiple Vulnerabilities"}],"tier":"poc_unverified"},"has_fix":null,"headline":"Sinapsi eSolar Improper Authentication","id":"CVE-2012-5864","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2012"},"n_packages":0,"n_references":5,"next":{"headline":"SQL injection in n/a","id":"CVE-2012-5865"},"packages":[],"prev":{"headline":"Sinapsi eSolar OS Command Injection","id":"CVE-2012-5863"},"products":["eSolar","eSolar DUO","eSolar Light"],"published":"2012-11-23","related":[{"cvss_score":10,"headline":"Sinapsi eSolar Hard-Coded Password","id":"CVE-2012-5862","kev_date_added":null,"published":"2012-11-23"},{"cvss_score":10,"headline":"Sinapsi eSolar OS Command Injection","id":"CVE-2012-5863","kev_date_added":null,"published":"2012-11-23"},{"cvss_score":7.8,"headline":"Sinapsi eSolar SQL Injection","id":"CVE-2012-5861","kev_date_added":null,"published":"2012-11-23"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-07-08","vendors":["Sinapsi"]},"summary":"Attackers can gain unauthorized administrative access to Sinapsi eSolar devices by directly visiting internal pages without authentication.","url":"https://insights.sbomify.com/CVE-2012-5864/"}