{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2013-0670 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2013-0670 yet. Limit exposure of the affected software until one is available.","what":"CVE-2013-0670 is a medium-severity vulnerability in n/a, published on 21 Mar 2013. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2013-0670 and fix it if it is affected.\n\nWhat it is: CVE-2013-0670 is a medium-severity vulnerability in n/a, published on 21 Mar 2013. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2013-0670 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2013-0670/ (Markdown: https://insights.sbomify.com/CVE-2013-0670/index.md)","id":"CVE-2013-0670","markdown":"https://insights.sbomify.com/CVE-2013-0670/index.md","name":"CVE-2013-0670","record":{"aliases":["GHSA-4fpf-24x8-fq8p"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens WinCC HMI","requires_auth":"none","summary":"Remote attackers can inject HTTP headers and split responses in Siemens WinCC HMI via crafted URLs, potentially bypassing security controls.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"wincc_tia_portal","vendor":"siemens"}],"cvss":{"score":4.3,"severity":"medium","source":"nvd","vector":"AV:N/AC:M/Au:N/C:N/I:P/A:N","version":"2.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in n/a","id":"CVE-2013-0670","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2013"},"n_packages":0,"n_references":2,"next":{"headline":"Path traversal in n/a","id":"CVE-2013-0671"},"packages":[],"prev":{"headline":"Denial of service in n/a","id":"CVE-2013-0669"},"products":["n/a"],"published":"2013-03-21","related":[{"cvss_score":4.6,"headline":"Weak cryptography in n/a","id":"CVE-2011-4515","kev_date_added":null,"published":"2013-03-21"},{"cvss_score":4.3,"headline":"Cross-site scripting in n/a","id":"CVE-2013-0667","kev_date_added":null,"published":"2013-03-21"},{"cvss_score":4.3,"headline":"Cross-site scripting in n/a","id":"CVE-2013-0668","kev_date_added":null,"published":"2013-03-21"},{"cvss_score":4,"headline":"Denial of service in n/a","id":"CVE-2013-0669","kev_date_added":null,"published":"2013-03-21"},{"cvss_score":4,"headline":"Path traversal in n/a","id":"CVE-2013-0671","kev_date_added":null,"published":"2013-03-21"},{"cvss_score":3.5,"headline":"Cross-site scripting in n/a","id":"CVE-2013-0672","kev_date_added":null,"published":"2013-03-21"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["n/a"]},"summary":"Remote attackers can inject HTTP headers and split responses in Siemens WinCC HMI via crafted URLs, potentially bypassing security controls.","url":"https://insights.sbomify.com/CVE-2013-0670/"}