{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2013-0679 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2013-0679 yet. Limit exposure of the affected software until one is available.","what":"CVE-2013-0679 is a medium-severity path traversal vulnerability in n/a, published on 21 Mar 2013. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2013-0679 and fix it if it is affected.\n\nWhat it is: CVE-2013-0679 is a medium-severity path traversal vulnerability in n/a, published on 21 Mar 2013. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2013-0679 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2013-0679/ (Markdown: https://insights.sbomify.com/CVE-2013-0679/index.md)","id":"CVE-2013-0679","markdown":"https://insights.sbomify.com/CVE-2013-0679/index.md","name":"CVE-2013-0679","record":{"aliases":["GHSA-rg3v-p933-jrxw"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens WinCC SCADA","requires_auth":"low_privilege","summary":"Authenticated attackers can read arbitrary files on Siemens WinCC web servers via directory traversal, exposing sensitive system data.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"simatic_pcs7","vendor":"siemens"},{"product":"wincc","vendor":"siemens"}],"cvss":{"score":4,"severity":"medium","source":"nvd","vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N","version":"2.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in n/a","id":"CVE-2013-0679","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2013"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in n/a","id":"CVE-2013-0680"},"packages":[],"prev":{"headline":"Information disclosure in n/a","id":"CVE-2013-0678"},"products":["n/a"],"published":"2013-03-21","related":[{"cvss_score":10,"headline":"Code injection in n/a","id":"CVE-2014-8551","kev_date_added":null,"published":"2014-11-26"},{"cvss_score":7.5,"headline":"SQL injection in n/a","id":"CVE-2013-3957","kev_date_added":null,"published":"2013-06-14"},{"cvss_score":7.5,"headline":"Hardcoded credentials in n/a","id":"CVE-2013-3958","kev_date_added":null,"published":"2013-06-14"},{"cvss_score":7.5,"headline":"SQL injection in n/a","id":"CVE-2012-3032","kev_date_added":null,"published":"2012-09-18"},{"cvss_score":6.9,"headline":"Privilege escalation in n/a","id":"CVE-2012-3015","kev_date_added":null,"published":"2012-07-26"},{"cvss_score":6.8,"headline":"Hardcoded credentials in n/a","id":"CVE-2014-4686","kev_date_added":null,"published":"2014-07-24"},{"cvss_score":6.8,"headline":"Memory corruption in n/a","id":"CVE-2013-0674","kev_date_added":null,"published":"2013-03-21"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["n/a"]},"summary":"Authenticated attackers can read arbitrary files on Siemens WinCC web servers via directory traversal, exposing sensitive system data.","url":"https://insights.sbomify.com/CVE-2013-0679/"}