{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2013-10058 exists.","fix":"No fix has been published for CVE-2013-10058 yet. Limit exposure of the affected software until one is available.","what":"CVE-2013-10058 is a high-severity command injection vulnerability in Linksys WRT160nv2, published on 1 Aug 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2013-10058 and fix it if it is affected.\n\nWhat it is: CVE-2013-10058 is a high-severity command injection vulnerability in Linksys WRT160nv2, published on 1 Aug 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2013-10058 exists.\n\nAffected product: Linksys WRT160nv2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2013-10058/ (Markdown: https://insights.sbomify.com/CVE-2013-10058/index.md)","id":"CVE-2013-10058","markdown":"https://insights.sbomify.com/CVE-2013-10058/index.md","name":"CVE-2013-10058","record":{"aliases":["GHSA-gg53-3xxr-77gw"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Linksys router","requires_auth":"high_privilege","summary":"Authenticated attackers can inject shell commands via the ping_size parameter in Linksys routers, leading to remote code execution.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"An authenticated OS command injection vulnerability exists in various Linksys router models (tested on WRT160Nv2) running firmware version v2.0.03 via the apply.cgi endpoint. The web interface fails to properly sanitize user-supplied input passed to the ping_size parameter during diagnostic operations. An attacker with valid credentials can inject arbitrary shell commands, enabling remote code execution.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":"2013-02-11","github_poc":0,"max_poc_stars":null,"metasploit":1,"nuclei":0,"refs":[{"date":"2013-02-11","kind":"metasploit","ref":"exploit/linux/http/linksys_wrt160nv2_apply_exec","stars":null,"title":"Linksys WRT160nv2 apply.cgi Remote Command Injection"}],"tier":"weaponised"},"has_fix":null,"headline":"Linksys Routers apply.cgi Remote Command Injection","id":"CVE-2013-10058","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2013"},"n_packages":0,"n_references":5,"next":{"headline":"D-Link Routers tools_vct.htm OS Command Injection","id":"CVE-2013-10059"},"packages":[],"prev":{"headline":"Synactis PDF In-The-Box ConnectToSynactic Stack-Based Buffer Overflow","id":"CVE-2013-10057"},"products":["WRT160nv2"],"published":"2025-08-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"BSD-3-Clause","name":"Metasploit"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-04-07","vendors":["Linksys"]},"summary":"Authenticated attackers can inject shell commands via the ping_size parameter in Linksys routers, leading to remote code execution.","url":"https://insights.sbomify.com/CVE-2013-10058/"}