{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2013-2796 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2013-2796 yet. Limit exposure of the affected software until one is available.","what":"CVE-2013-2796 is a medium-severity vulnerability in n/a, published on 9 Aug 2013. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2013-2796 and fix it if it is affected.\n\nWhat it is: CVE-2013-2796 is a medium-severity vulnerability in n/a, published on 9 Aug 2013. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2013-2796 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2013-2796/ (Markdown: https://insights.sbomify.com/CVE-2013-2796/index.md)","id":"CVE-2013-2796","markdown":"https://insights.sbomify.com/CVE-2013-2796/index.md","name":"CVE-2013-2796","record":{"aliases":["GHSA-fxqp-5cfq-qj7q"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA software","requires_auth":"none","summary":"Remote attackers can read arbitrary files, access intranet servers, or cause denial of service in Schneider Electric SCADA systems via XML External Entity injection.","user_interaction":"not_required","vuln_class":"xxe"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"citectscada","vendor":"schneider-electric"},{"product":"powerlogic_scada","vendor":"schneider-electric"},{"product":"vijeo_citect","vendor":"schneider-electric"}],"cvss":{"score":6.9,"severity":"medium","source":"nvd","vector":"AV:L/AC:M/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-264","name":null}],"description":"Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"XML external entity in n/a","id":"CVE-2013-2796","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xxe","year":"2013"},"n_packages":0,"n_references":2,"next":{"headline":"Denial of service in n/a","id":"CVE-2013-2798"},"packages":[],"prev":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2013-2795"},"products":["n/a"],"published":"2013-08-09","related":[{"cvss_score":7.8,"headline":"Information disclosure in AVEVA Vijeo Citect and CitectSCADA","id":"CVE-2019-10981","kev_date_added":null,"published":"2019-05-31"},{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2013-2824","kev_date_added":null,"published":"2014-02-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["n/a"]},"summary":"Remote attackers can read arbitrary files, access intranet servers, or cause denial of service in Schneider Electric SCADA systems via XML External Entity injection.","url":"https://insights.sbomify.com/CVE-2013-2796/"}