{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2013-2806 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2013-2806 yet. Limit exposure of the affected software until one is available.","what":"CVE-2013-2806 is a high-severity vulnerability in Rockwell Automation RSLinx Enterprise Software, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2013-2806 and fix it if it is affected.\n\nWhat it is: CVE-2013-2806 is a high-severity vulnerability in Rockwell Automation RSLinx Enterprise Software, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2013-2806 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation RSLinx Enterprise Software. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2013-2806/ (Markdown: https://insights.sbomify.com/CVE-2013-2806/index.md)","id":"CVE-2013-2806","markdown":"https://insights.sbomify.com/CVE-2013-2806/index.md","name":"CVE-2013-2806","record":{"aliases":["GHSA-7934-59fw-r79m"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial automation software","requires_auth":"none","summary":"An attacker can crash the RSLinx Enterprise service by sending a malformed UDP packet, causing a denial of service in industrial control systems.","user_interaction":"not_required","vuln_class":"integer_overflow"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"rslinx_enterprise","vendor":"rockwellautomation"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-190","name":"Integer Overflow or Wraparound"}],"description":"Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Integer overflow in RSLinx Enterprise Software","id":"CVE-2013-2806","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"integer_overflow","year":"2013"},"n_packages":0,"n_references":1,"next":{"headline":"Integer overflow in RSLinx Enterprise Software","id":"CVE-2013-2807"},"packages":[],"prev":{"headline":"Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR","id":"CVE-2013-2805"},"products":["RSLinx Enterprise Software"],"published":"2019-03-26","related":[{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2012-4715","kev_date_added":null,"published":"2013-04-18"},{"cvss_score":7.5,"headline":"Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR","id":"CVE-2013-2805","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":7.5,"headline":"Integer overflow in RSLinx Enterprise Software","id":"CVE-2013-2807","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":7.1,"headline":"Denial of service in n/a","id":"CVE-2012-4695","kev_date_added":null,"published":"2013-04-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["Rockwell Automation"]},"summary":"An attacker can crash the RSLinx Enterprise service by sending a malformed UDP packet, causing a denial of service in industrial control systems.","url":"https://insights.sbomify.com/CVE-2013-2806/"}