CVE-2013-3634 Auth bypass in n/a

High 7.5 Published Updated

Attackers can execute SNMP commands without valid credentials due to insufficient credential checks in SCALANCE switches.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2013-3634?

CVE-2013-3634 is a high-severity authentication bypass vulnerability in n/a, published on 24 May 2013. An attacker can exploit it over the internet without logging in, with no action from the victim.

Official description

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.

Weakness: CWE-20

Which versions are affected by CVE-2013-3634?

It affects 7 products.

Products include Siemens Scalance X200-4p Irt, Siemens Scalance X200irt Firmware, Siemens Scalance X201-3p Irt, Siemens Scalance X202-2irt, Siemens Scalance X202-2p Irt, Siemens Scalance X204irt and 1 more.

How do I fix CVE-2013-3634?

No fix has been published for CVE-2013-3634 yet. Limit exposure of the affected software until one is available.

Upgrade, and rotate credentials and sessions that may have been exposed. More about Authentication bypass.

Is CVE-2013-3634 being exploited?

There is no known exploitation of CVE-2013-3634 in the wild and no public exploit code.