{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2014-0751 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-0751 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-0751 is a medium-severity path traversal vulnerability in GE Proficy HMI/SCADA - CIMPLICITY, published on 25 Jan 2014. It can be exploited over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-0751 and fix it if it is affected.\n\nWhat it is: CVE-2014-0751 is a medium-severity path traversal vulnerability in GE Proficy HMI/SCADA - CIMPLICITY, published on 25 Jan 2014. It can be exploited over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-0751 in the wild and no public exploit code.\n\nAffected product: GE Proficy HMI/SCADA - CIMPLICITY. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-0751/ (Markdown: https://insights.sbomify.com/CVE-2014-0751/index.md)","id":"CVE-2014-0751","markdown":"https://insights.sbomify.com/CVE-2014-0751/index.md","name":"CVE-2014-0751","record":{"aliases":["GHSA-5q8q-px6g-7r9f"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"GE SCADA HMI","requires_auth":"unknown","summary":"An attacker can exploit a path traversal flaw in GE Proficy CIMPLICITY to upload and execute arbitrary shell code via the web server.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"intelligent_platforms_proficy_hmi\\%2fscada_cimplicity","vendor":"ge"},{"product":"intelligent_platforms_proficy_hmi\\/scada_cimplicity","vendor":"ge"},{"product":"intelligent_platforms_proficy_process_systems_with_cimplicity","vendor":"ge"}],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"AV:N/AC:M/Au:N/C:P/I:P/A:P","version":"2.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"The CIMPLICITY Web-based access component, CimWebServer, does not check \nthe location of shell files being loaded into the system. By modifying \nthe source location, an attacker could send shell code to the \nCimWebServer which would deploy the nefarious files as part of any SCADA\n project. This could allow the attacker to execute arbitrary code.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"GE Proficy HMI/SCADA Path Traversal","id":"CVE-2014-0751","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2014"},"n_packages":0,"n_references":3,"next":{"headline":"Ecava IntegraXor Exposure of Access Control List Files to an Unauthorized Control Sphere","id":"CVE-2014-0752"},"packages":[],"prev":{"headline":"GE Proficy HMI/SCADA Path Traversal","id":"CVE-2014-0750"},"products":["Proficy HMI/SCADA - CIMPLICITY","Proficy Process Systems with CIMPLICITY"],"published":"2014-01-25","related":[{"cvss_score":7.5,"headline":"GE Proficy HMI/SCADA Path Traversal","id":"CVE-2014-0750","kev_date_added":null,"published":"2014-01-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-08-22","vendors":["GE"]},"summary":"An attacker can exploit a path traversal flaw in GE Proficy CIMPLICITY to upload and execute arbitrary shell code via the web server.","url":"https://insights.sbomify.com/CVE-2014-0751/"}