{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2014-0774 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-0774 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-0774 is a medium-severity memory corruption vulnerability in Schneider Electric TLXCDLFOFS33, published on 28 Feb 2014. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2014-0774 and fix it if it is affected.\n\nWhat it is: CVE-2014-0774 is a medium-severity memory corruption vulnerability in Schneider Electric TLXCDLFOFS33, published on 28 Feb 2014. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2014-0774 in the wild and no public exploit code.\n\nAffected product: Schneider Electric TLXCDLFOFS33. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-0774/ (Markdown: https://insights.sbomify.com/CVE-2014-0774/index.md)","id":"CVE-2014-0774","markdown":"https://insights.sbomify.com/CVE-2014-0774/index.md","name":"CVE-2014-0774","record":{"aliases":["GHSA-23h3-v846-4gxf"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"OPC Factory Server","requires_auth":"low_privilege","summary":"Local attackers can exploit a stack buffer overflow in the C++ sample client via a malformed configuration file to gain elevated privileges.","user_interaction":"required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ofs_test_client_tlxcdlfofs33","vendor":"schneider-electric"},{"product":"ofs_test_client_tlxcdltofs33","vendor":"schneider-electric"},{"product":"ofs_test_client_tlxcdluofs33","vendor":"schneider-electric"},{"product":"ofs_test_client_tlxcdstofs33","vendor":"schneider-electric"},{"product":"ofs_test_client_tlxcdsuofs33","vendor":"schneider-electric"},{"product":"opc_factory_server","vendor":"schneider-electric"}],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"AV:L/AC:L/Au:S/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Schneider Electric OFS Stack Buffer Overflow","id":"CVE-2014-0774","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2014"},"n_packages":0,"n_references":3,"next":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2014-0775"},"packages":[],"prev":{"headline":"Advantech WebAccess Command Injection","id":"CVE-2014-0773"},"products":["TLXCDLFOFS33","TLXCDLTOFS33","TLXCDLUOFS33","TLXCDSTOFS33","TLXCDSUOFS33"],"published":"2014-02-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-09-24","vendors":["Schneider Electric"]},"summary":"Local attackers can exploit a stack buffer overflow in the C++ sample client via a malformed configuration file to gain elevated privileges.","url":"https://insights.sbomify.com/CVE-2014-0774/"}