{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2014-1698 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-1698 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-1698 is a medium-severity path traversal vulnerability in n/a, published on 7 Feb 2014. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-1698 and fix it if it is affected.\n\nWhat it is: CVE-2014-1698 is a medium-severity path traversal vulnerability in n/a, published on 7 Feb 2014. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-1698 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-1698/ (Markdown: https://insights.sbomify.com/CVE-2014-1698/index.md)","id":"CVE-2014-1698","markdown":"https://insights.sbomify.com/CVE-2014-1698/index.md","name":"CVE-2014-1698","record":{"aliases":["GHSA-5x5r-8mwc-gh65"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA HMI software","requires_auth":"none","summary":"Remote attackers can read arbitrary files from Siemens SIMATIC WinCC OA via crafted packets, exposing sensitive system data.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"simatic_wincc_open_architecture","vendor":"siemens"}],"cvss":{"score":5,"severity":"medium","source":"nvd","vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","version":"2.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in n/a","id":"CVE-2014-1698","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2014"},"n_packages":0,"n_references":6,"next":{"headline":"Denial of service in n/a","id":"CVE-2014-1699"},"packages":[],"prev":{"headline":"Code injection in n/a","id":"CVE-2014-1697"},"products":["n/a"],"published":"2014-02-07","related":[{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2018-3991","kev_date_added":null,"published":"2019-02-05"},{"cvss_score":9.1,"headline":"Privilege escalation in SIMATIC WinCC OA V3.14 and prior","id":"CVE-2018-13799","kev_date_added":null,"published":"2018-09-12"},{"cvss_score":7.5,"headline":"Code injection in n/a","id":"CVE-2014-1697","kev_date_added":null,"published":"2014-02-07"},{"cvss_score":5,"headline":"Weak cryptography in n/a","id":"CVE-2014-1696","kev_date_added":null,"published":"2014-02-07"},{"cvss_score":5,"headline":"Denial of service in n/a","id":"CVE-2014-1699","kev_date_added":null,"published":"2014-02-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Remote attackers can read arbitrary files from Siemens SIMATIC WinCC OA via crafted packets, exposing sensitive system data.","url":"https://insights.sbomify.com/CVE-2014-1698/"}