{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2014-2343 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-2343 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-2343 is a low-severity denial of service vulnerability in Triangle MicroWorks SCADA Data Gateway, published on 30 May 2014. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-2343 and fix it if it is affected.\n\nWhat it is: CVE-2014-2343 is a low-severity denial of service vulnerability in Triangle MicroWorks SCADA Data Gateway, published on 30 May 2014. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-2343 in the wild and no public exploit code.\n\nAffected product: Triangle MicroWorks SCADA Data Gateway. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-2343/ (Markdown: https://insights.sbomify.com/CVE-2014-2343/index.md)","id":"CVE-2014-2343","markdown":"https://insights.sbomify.com/CVE-2014-2343/index.md","name":"CVE-2014-2343","record":{"aliases":["GHSA-fpcj-qxxf-c8wx"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADA Data Gateway","requires_auth":"none","summary":"Physically proximate attackers can cause denial of service in Triangle MicroWorks SCADA Data Gateway via crafted DNP requests over serial lines.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"scada_data_gateway","vendor":"trianglemicroworks"}],"cvss":{"score":1.2,"severity":"low","source":"cna","vector":"AV:L/AC:H/Au:N/C:N/I:N/A:P","version":"2.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"},{"id":"CWE-400","name":"Uncontrolled Resource Consumption"}],"description":"Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Triangle MicroWorks SCADA Data Gateway Resource Exhaustion","id":"CVE-2014-2343","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2014"},"n_packages":0,"n_references":2,"next":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2014-2344"},"packages":[],"prev":{"headline":"Triangle MicroWorks SCADA Data Gateway Resource Exhaustion","id":"CVE-2014-2342"},"products":["SCADA Data Gateway"],"published":"2014-05-30","related":[{"cvss_score":9.8,"headline":"Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability","id":"CVE-2023-39457","kev_date_added":null,"published":"2024-05-03"},{"cvss_score":9.8,"headline":"Memory corruption in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","id":"CVE-2020-10611","kev_date_added":null,"published":"2020-04-15"},{"cvss_score":8.2,"headline":"Other in SCADA Data Gateway","id":"CVE-2023-2186","kev_date_added":null,"published":"2023-06-07"},{"cvss_score":7.8,"headline":"Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability","id":"CVE-2023-39459","kev_date_added":null,"published":"2024-05-03"},{"cvss_score":7.5,"headline":"Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability","id":"CVE-2023-39465","kev_date_added":null,"published":"2024-05-03"},{"cvss_score":7.5,"headline":"Information disclosure in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","id":"CVE-2020-10613","kev_date_added":null,"published":"2020-04-15"},{"cvss_score":7.5,"headline":"Memory corruption in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","id":"CVE-2020-10615","kev_date_added":null,"published":"2020-04-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-10-02","vendors":["Triangle MicroWorks"]},"summary":"Physically proximate attackers can cause denial of service in Triangle MicroWorks SCADA Data Gateway via crafted DNP requests over serial lines.","url":"https://insights.sbomify.com/CVE-2014-2343/"}