{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2014-2356 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-2356 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-2356 is a medium-severity vulnerability in Innominate mGuard, published on 30 Jul 2014. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-2356 and fix it if it is affected.\n\nWhat it is: CVE-2014-2356 is a medium-severity vulnerability in Innominate mGuard, published on 30 Jul 2014. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-2356 in the wild and no public exploit code.\n\nAffected product: Innominate mGuard. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-2356/ (Markdown: https://insights.sbomify.com/CVE-2014-2356/index.md)","id":"CVE-2014-2356","markdown":"https://insights.sbomify.com/CVE-2014-2356/index.md","name":"CVE-2014-2356","record":{"aliases":["GHSA-p4h7-mjq9-xwq7"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Innominate mGuard","requires_auth":"none","summary":"Remote attackers can obtain sensitive information by downloading snapshots without authentication from Innominate mGuard devices.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"mguard_firmware","vendor":"innominate"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"AV:N/AC:M/Au:N/C:P/I:N/A:N","version":"2.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Innominate mGuard before 7.6.4 and 8.x before 8.0.3 does not require authentication for snapshot downloads, which allows remote attackers to obtain sensitive information via a crafted HTTPS request.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Innominate mGuard Exposure of Sensitive Information to an Unauthorized Actor","id":"CVE-2014-2356","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2014"},"n_packages":0,"n_references":1,"next":{"headline":"SUBNET SubSTATION Server 2 Telegyr 8979 Master Protocol Improper Input Validation","id":"CVE-2014-2357"},"packages":[],"prev":{"headline":"GE Proficy HMI/SCADA CIMPLICITY CimView","id":"CVE-2014-2355"},"products":["mGuard"],"published":"2014-07-30","related":[{"cvss_score":8.5,"headline":"Innominate mGuard Improper Privilege Management","id":"CVE-2014-9193","kev_date_added":null,"published":"2014-12-20"},{"cvss_score":7.1,"headline":"Weak cryptography in n/a","id":"CVE-2012-3006","kev_date_added":null,"published":"2012-06-19"},{"cvss_score":4,"headline":"Denial of service in n/a","id":"CVE-2015-3966","kev_date_added":null,"published":"2015-08-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-10-03","vendors":["Innominate"]},"summary":"Remote attackers can obtain sensitive information by downloading snapshots without authentication from Innominate mGuard devices.","url":"https://insights.sbomify.com/CVE-2014-2356/"}