{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2014-2909 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-2909 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-2909 is a medium-severity vulnerability in n/a, published on 25 Apr 2014. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-2909 and fix it if it is affected.\n\nWhat it is: CVE-2014-2909 is a medium-severity vulnerability in n/a, published on 25 Apr 2014. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-2909 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-2909/ (Markdown: https://insights.sbomify.com/CVE-2014-2909/index.md)","id":"CVE-2014-2909","markdown":"https://insights.sbomify.com/CVE-2014-2909/index.md","name":"CVE-2014-2909","record":{"aliases":["GHSA-53rw-gv4m-q3jg"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens PLC","requires_auth":"none","summary":"Remote attackers can inject arbitrary HTTP headers into Siemens SIMATIC S7-1200 devices via CRLF injection in the integrated web server.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"simatic_s7_cpu-1211c","vendor":"siemens"},{"product":"simatic_s7_cpu_1200_firmware","vendor":"siemens"},{"product":"simatic_s7_cpu_1212c","vendor":"siemens"},{"product":"simatic_s7_cpu_1214c","vendor":"siemens"},{"product":"simatic_s7_cpu_1215c","vendor":"siemens"},{"product":"simatic_s7_cpu_1217c","vendor":"siemens"}],"cvss":{"score":5.8,"severity":"medium","source":"nvd","vector":"AV:N/AC:M/Au:N/C:N/I:P/A:P","version":"2.0"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"}],"description":"CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in n/a","id":"CVE-2014-2909","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2014"},"n_packages":0,"n_references":3,"next":{"headline":"Command injection in n/a","id":"CVE-2014-2913"},"packages":[],"prev":{"headline":"Cross-site scripting in n/a","id":"CVE-2014-2908"},"products":["n/a"],"published":"2014-04-25","related":[{"cvss_score":8.3,"headline":"Weak cryptography in n/a","id":"CVE-2014-2250","kev_date_added":null,"published":"2014-03-22"},{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2014-2254","kev_date_added":null,"published":"2014-03-22"},{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2014-2256","kev_date_added":null,"published":"2014-03-22"},{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2014-2258","kev_date_added":null,"published":"2014-03-22"},{"cvss_score":6.1,"headline":"Denial of service in n/a","id":"CVE-2014-2252","kev_date_added":null,"published":"2014-03-22"},{"cvss_score":4.3,"headline":"Cross-site scripting in n/a","id":"CVE-2014-2908","kev_date_added":null,"published":"2014-04-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Remote attackers can inject arbitrary HTTP headers into Siemens SIMATIC S7-1200 devices via CRLF injection in the integrated web server.","url":"https://insights.sbomify.com/CVE-2014-2909/"}