{"answers":{"affected":"It affects 12 products.","exploited":"There is no known exploitation of CVE-2014-5394 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-5394 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-5394 is a medium-severity vulnerability in n/a, published on 8 Jan 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-5394 and fix it if it is affected.\n\nWhat it is: CVE-2014-5394 is a medium-severity vulnerability in n/a, published on 8 Jan 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-5394 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-5394/ (Markdown: https://insights.sbomify.com/CVE-2014-5394/index.md)","id":"CVE-2014-5394","markdown":"https://insights.sbomify.com/CVE-2014-5394/index.md","name":"CVE-2014-5394","record":{"aliases":["GHSA-ghjw-c2v5-8vjh"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Huawei Campus switch","requires_auth":"none","summary":"Remote attackers can enumerate usernames on Huawei Campus switches via SSH maintenance terminal access, exposing sensitive user information.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"s2300_firmware","vendor":"huawei"},{"product":"s2700_firmware","vendor":"huawei"},{"product":"s3300_firmware","vendor":"huawei"},{"product":"s3700_firmware","vendor":"huawei"},{"product":"s5300_firmware","vendor":"huawei"},{"product":"s5700_firmware","vendor":"huawei"},{"product":"s6300_firmware","vendor":"huawei"},{"product":"s6700_firmware","vendor":"huawei"},{"product":"s7700_firmware","vendor":"huawei"},{"product":"s9300_firmware","vendor":"huawei"},{"product":"s9300e_firmware","vendor":"huawei"},{"product":"s9700_firmware","vendor":"huawei"}],"cvss":{"score":5.9,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Multiple Huawei Campus switches allow remote attackers to enumerate usernames via vectors involving use of SSH by the maintenance terminal.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2014-5394","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2014"},"n_packages":0,"n_references":3,"next":{"headline":"Cross-site request forgery in n/a","id":"CVE-2014-5395"},"packages":[],"prev":{"headline":"Path traversal in n/a","id":"CVE-2014-5393"},"products":["n/a"],"published":"2018-01-08","related":[{"cvss_score":7.5,"headline":"Denial of service in S9300,S2300,S3300,S5300,S6300 S9300 with software V100R006C00SPC500??S9300 with software V100R006C00SPC800,S2300,S3300,S5300,S6300 with software V100R006C00SPC800,V100R006C01SPC100, V100R006C03","id":"CVE-2014-3223","kev_date_added":null,"published":"2017-04-02"},{"cvss_score":7.5,"headline":"Denial of service in n/a","id":"CVE-2015-8676","kev_date_added":null,"published":"2016-04-14"},{"cvss_score":6.5,"headline":"Denial of service in n/a","id":"CVE-2015-8677","kev_date_added":null,"published":"2016-04-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Remote attackers can enumerate usernames on Huawei Campus switches via SSH maintenance terminal access, exposing sensitive user information.","url":"https://insights.sbomify.com/CVE-2014-5394/"}