{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2014-5406 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-5406 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-5406 is a high-severity missing authorization vulnerability in Hospira LifeCare PCA Infusion System, published on 6 Jul 2015. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-5406 and fix it if it is affected.\n\nWhat it is: CVE-2014-5406 is a high-severity missing authorization vulnerability in Hospira LifeCare PCA Infusion System, published on 6 Jul 2015. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-5406 in the wild and no public exploit code.\n\nAffected product: Hospira LifeCare PCA Infusion System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-5406/ (Markdown: https://insights.sbomify.com/CVE-2014-5406/index.md)","id":"CVE-2014-5406","markdown":"https://insights.sbomify.com/CVE-2014-5406/index.md","name":"CVE-2014-5406","record":{"aliases":["GHSA-vxf4-qh89-w2r6"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_modify","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical infusion pump","requires_auth":"none","summary":"Remote attackers can modify medication settings and data on Hospira LifeCare PCA Infusion Systems without authentication via network ports.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"lifecare_pcainfusion_firmware","vendor":"hospira"}],"cvss":{"score":7.6,"severity":"high","source":"cna","vector":"AV:N/AC:H/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"}],"description":"The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port.  NOTE: this issue might overlap CVE-2015-3459.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hospira LifeCare PCA Infusion System","id":"CVE-2014-5406","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2014"},"n_packages":0,"n_references":4,"next":{"headline":"Schneider Electric VAMPSET Stack-based Buffer Overflow","id":"CVE-2014-5407"},"packages":[],"prev":{"headline":"Hospira MedNet Use of Hard-coded Password","id":"CVE-2014-5405"},"products":["LifeCare PCA Infusion System"],"published":"2015-07-06","related":[{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2015-3955","kev_date_added":null,"published":"2015-07-06"},{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2015-3958","kev_date_added":null,"published":"2015-07-06"},{"cvss_score":5,"headline":"Hardcoded credentials in n/a","id":"CVE-2015-1011","kev_date_added":null,"published":"2015-07-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-11-03","vendors":["Hospira"]},"summary":"Remote attackers can modify medication settings and data on Hospira LifeCare PCA Infusion Systems without authentication via network ports.","url":"https://insights.sbomify.com/CVE-2014-5406/"}