{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2014-5407 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-5407 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-5407 is a medium-severity memory corruption vulnerability in Schneider Electric VAMPSET, published on 15 Sep 2014. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2014-5407 and fix it if it is affected.\n\nWhat it is: CVE-2014-5407 is a medium-severity memory corruption vulnerability in Schneider Electric VAMPSET, published on 15 Sep 2014. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2014-5407 in the wild and no public exploit code.\n\nAffected product: Schneider Electric VAMPSET. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-5407/ (Markdown: https://insights.sbomify.com/CVE-2014-5407/index.md)","id":"CVE-2014-5407","markdown":"https://insights.sbomify.com/CVE-2014-5407/index.md","name":"CVE-2014-5407","record":{"aliases":["GHSA-5865-xr2h-gxr4"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"VAMPSET power system","requires_auth":"low_privilege","summary":"Local attackers can cause a denial of service in Schneider Electric VAMPSET by providing malformed setting or disturbance recording files.","user_interaction":"required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"vampset","vendor":"schneider-electric"}],"cvss":{"score":4.1,"severity":"medium","source":"cna","vector":"AV:L/AC:M/Au:S/C:P/I:P/A:P","version":"2.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Schneider Electric VAMPSET Stack-based Buffer Overflow","id":"CVE-2014-5407","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2014"},"n_packages":0,"n_references":3,"next":{"headline":"Nordex NC2 Cross-site Scripting","id":"CVE-2014-5408"},"packages":[],"prev":{"headline":"Hospira LifeCare PCA Infusion System","id":"CVE-2014-5406"},"products":["VAMPSET"],"published":"2014-09-15","related":[{"cvss_score":5.5,"headline":"Memory corruption in VAMPSET","id":"CVE-2017-7967","kev_date_added":null,"published":"2017-05-09"},{"cvss_score":4.4,"headline":"Memory corruption in n/a","id":"CVE-2014-8390","kev_date_added":null,"published":"2015-04-03"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-11-03","vendors":["Schneider Electric"]},"summary":"Local attackers can cause a denial of service in Schneider Electric VAMPSET by providing malformed setting or disturbance recording files.","url":"https://insights.sbomify.com/CVE-2014-5407/"}