{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2014-5413 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-5413 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-5413 is a medium-severity vulnerability in Schneider Electric ClearSCADA, published on 18 Sep 2014. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-5413 and fix it if it is affected.\n\nWhat it is: CVE-2014-5413 is a medium-severity vulnerability in Schneider Electric ClearSCADA, published on 18 Sep 2014. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-5413 in the wild and no public exploit code.\n\nAffected product: Schneider Electric ClearSCADA. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-5413/ (Markdown: https://insights.sbomify.com/CVE-2014-5413/index.md)","id":"CVE-2014-5413","markdown":"https://insights.sbomify.com/CVE-2014-5413/index.md","name":"CVE-2014-5413","record":{"aliases":["GHSA-wxww-p46r-jjv2"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA Expert ClearSCADA","requires_auth":"none","summary":"Remote attackers can spoof servers in Schneider Electric SCADA Expert ClearSCADA due to the use of the weak MD5 algorithm for X.509 certificates.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"clearscada","vendor":"aveva"},{"product":"scada_expert_clearscada","vendor":"schneider-electric"}],"cvss":{"score":6.4,"severity":"medium","source":"cna","vector":"AV:N/AC:L/Au:N/C:P/I:P/A:N","version":"2.0"},"cwes":[{"id":"CWE-310","name":null}],"description":"Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Schneider Electric SCADA Expert ClearSCADA Cryptographic Issues","id":"CVE-2014-5413","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2014"},"n_packages":0,"n_references":2,"next":{"headline":"Beckhoff Embedded PC Images and TwinCAT Components Improper Restriction of Excessive Authentication Attempts","id":"CVE-2014-5414"},"packages":[],"prev":{"headline":"Schneider Electric SCADA Expert ClearSCADA Improper Authentication","id":"CVE-2014-5412"},"products":["ClearSCADA","SCADA Expert ClearSCADA"],"published":"2014-09-18","related":[{"cvss_score":10,"headline":"Use after free in n/a","id":"CVE-2011-3143","kev_date_added":null,"published":"2011-08-16"},{"cvss_score":7.5,"headline":"Denial of service in ClearSCADA","id":"CVE-2017-6021","kev_date_added":null,"published":"2018-05-14"},{"cvss_score":7.5,"headline":"Memory corruption in ClearSCADA","id":"CVE-2017-9962","kev_date_added":null,"published":"2017-09-25"},{"cvss_score":6.8,"headline":"Memory corruption in ClearSCADA","id":"CVE-2014-0779","kev_date_added":null,"published":"2014-03-14"},{"cvss_score":6.4,"headline":"Schneider Electric SCADA Expert ClearSCADA Improper Authentication","id":"CVE-2014-5412","kev_date_added":null,"published":"2014-09-18"},{"cvss_score":4.9,"headline":"Schneider Electric SCADA Expert ClearSCADA Cross-site Scripting","id":"CVE-2014-5411","kev_date_added":null,"published":"2014-09-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-11-04","vendors":["Schneider Electric"]},"summary":"Remote attackers can spoof servers in Schneider Electric SCADA Expert ClearSCADA due to the use of the weak MD5 algorithm for X.509 certificates.","url":"https://insights.sbomify.com/CVE-2014-5413/"}