{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2014-5432 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-5432 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-5432 is a critical authentication bypass vulnerability in Baxter SIGMA Spectrum Infusion System, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-5432 and fix it if it is affected.\n\nWhat it is: CVE-2014-5432 is a critical authentication bypass vulnerability in Baxter SIGMA Spectrum Infusion System, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-5432 in the wild and no public exploit code.\n\nAffected product: Baxter SIGMA Spectrum Infusion System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-5432/ (Markdown: https://insights.sbomify.com/CVE-2014-5432/index.md)","id":"CVE-2014-5432","markdown":"https://insights.sbomify.com/CVE-2014-5432/index.md","name":"CVE-2014-5432","record":{"aliases":["GHSA-7gh3-72p7-5h77"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["privilege_escalation","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Infusion pump system","requires_auth":"none","summary":"Remote attackers can bypass SSH authentication on the wireless battery module to modify configurations and access credentials in Baxter infusion systems.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"sigma_spectrum_infusion_system_firmware","vendor":"baxter"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"},{"id":"CWE-592","name":"DEPRECATED: Authentication Bypass Issues"}],"description":"Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled from the WBM. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in SIGMA Spectrum Infusion System","id":"CVE-2014-5432","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2014"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in SIGMA Spectrum Infusion System","id":"CVE-2014-5433"},"packages":[],"prev":{"headline":"Hardcoded credentials in SIGMA Spectrum Infusion System","id":"CVE-2014-5431"},"products":["SIGMA Spectrum Infusion System"],"published":"2019-03-26","related":[{"cvss_score":9.8,"headline":"Information disclosure in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12040","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Security feature bypass in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12043","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Hardcoded credentials in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12045","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Hardcoded credentials in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12047","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Information disclosure in SIGMA Spectrum Infusion System","id":"CVE-2014-5433","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":9.8,"headline":"Hardcoded credentials in SIGMA Spectrum Infusion System","id":"CVE-2014-5434","kev_date_added":null,"published":"2019-03-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["Baxter"]},"summary":"Remote attackers can bypass SSH authentication on the wireless battery module to modify configurations and access credentials in Baxter infusion systems.","url":"https://insights.sbomify.com/CVE-2014-5432/"}