{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2014-8372 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2014-8372 yet. Limit exposure of the affected software until one is available.","what":"CVE-2014-8372 is a medium-severity vulnerability in n/a, published on 11 Dec 2014. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2014-8372 and fix it if it is affected.\n\nWhat it is: CVE-2014-8372 is a medium-severity vulnerability in n/a, published on 11 Dec 2014. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2014-8372 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2014-8372/ (Markdown: https://insights.sbomify.com/CVE-2014-8372/index.md)","id":"CVE-2014-8372","markdown":"https://insights.sbomify.com/CVE-2014-8372/index.md","name":"CVE-2014-8372","record":{"aliases":["GHSA-x9wv-pg9w-7fpw"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"AirWatch on-premise","requires_auth":"low_privilege","summary":"Authenticated users can access sensitive organizational data from other tenants due to insecure direct object references in AirWatch.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"airwatch","vendor":"vmware"}],"cvss":{"score":4,"severity":"medium","source":"nvd","vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N","version":"2.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"AirWatch by VMware On-Premise 7.3.x before 7.3.3.0 (FP3) allows remote authenticated users to obtain the organizational information and statistics from arbitrary tenants via vectors involving a direct object reference.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2014-8372","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2014"},"n_packages":0,"n_references":2,"next":{"headline":"Privilege escalation in n/a","id":"CVE-2014-8373"},"packages":[],"prev":{"headline":"Security feature bypass in n/a","id":"CVE-2014-8371"},"products":["n/a"],"published":"2014-12-11","related":[{"cvss_score":8.8,"headline":"Cross-site request forgery in AirWatch Console","id":"CVE-2017-4951","kev_date_added":null,"published":"2018-01-29"},{"cvss_score":7.8,"headline":"Cross-site scripting in VMware AirWatch Console (AWC)","id":"CVE-2017-4931","kev_date_added":null,"published":"2017-11-16"},{"cvss_score":5.4,"headline":"Cross-site scripting in VMware AirWatch Console (AWC)","id":"CVE-2017-4930","kev_date_added":null,"published":"2017-11-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Authenticated users can access sensitive organizational data from other tenants due to insecure direct object references in AirWatch.","url":"https://insights.sbomify.com/CVE-2014-8372/"}