{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2015-1014 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2015-1014 yet. Limit exposure of the affected software until one is available.","what":"CVE-2015-1014 is a high-severity vulnerability in Schneider Electric OFS v3.5, published on 25 Mar 2019. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2015-1014 and fix it if it is affected.\n\nWhat it is: CVE-2015-1014 is a high-severity vulnerability in Schneider Electric OFS v3.5, published on 25 Mar 2019. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2015-1014 in the wild and no public exploit code.\n\nAffected product: Schneider Electric OFS v3.5. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2015-1014/ (Markdown: https://insights.sbomify.com/CVE-2015-1014/index.md)","id":"CVE-2015-1014","markdown":"https://insights.sbomify.com/CVE-2015-1014/index.md","name":"CVE-2015-1014","record":{"aliases":["GHSA-f7j5-fwrm-8242"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADA Expert Vijeo Citect","requires_auth":"low_privilege","summary":"Local attackers can execute arbitrary code or cause denial of service by loading a crafted DLL in Schneider Electric SCADA systems.","user_interaction":"required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"opc_factory_server","vendor":"schneider-electric"}],"cvss":{"score":7.3,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-427","name":"Uncontrolled Search Path Element"}],"description":"A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in OFS v3.5","id":"CVE-2015-1014","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2015"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in n/a","id":"CVE-2015-1015"},"packages":[],"prev":{"headline":"SQL injection in n/a","id":"CVE-2015-1013"},"products":["OFS v3.5"],"published":"2019-03-25","related":[{"cvss_score":5,"headline":"XML external entity in OPC Factory Server (OFS)","id":"CVE-2023-2161","kev_date_added":null,"published":"2023-05-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["Schneider Electric"]},"summary":"Local attackers can execute arbitrary code or cause denial of service by loading a crafted DLL in Schneider Electric SCADA systems.","url":"https://insights.sbomify.com/CVE-2015-1014/"}