{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2015-2822 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2015-2822 yet. Limit exposure of the affected software until one is available.","what":"CVE-2015-2822 is a medium-severity denial of service vulnerability in n/a, published on 8 Apr 2015. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2015-2822 and fix it if it is affected.\n\nWhat it is: CVE-2015-2822 is a medium-severity denial of service vulnerability in n/a, published on 8 Apr 2015. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2015-2822 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2015-2822/ (Markdown: https://insights.sbomify.com/CVE-2015-2822/index.md)","id":"CVE-2015-2822","markdown":"https://insights.sbomify.com/CVE-2015-2822/index.md","name":"CVE-2015-2822","record":{"aliases":["GHSA-fm48-43fc-v57r"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens HMI Panel","requires_auth":"none","summary":"Man-in-the-middle attackers can cause denial of service on Siemens SIMATIC HMI panels via crafted packets on TCP port 102.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"wincc","vendor":"siemens"}],"cvss":{"score":4.3,"severity":"medium","source":"nvd","vector":"AV:N/AC:M/Au:N/C:N/I:N/A:P","version":"2.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in n/a","id":"CVE-2015-2822","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2015"},"n_packages":0,"n_references":3,"next":{"headline":"Auth bypass in n/a","id":"CVE-2015-2823"},"packages":[],"prev":{"headline":"Missing authorization in n/a","id":"CVE-2015-2821"},"products":["n/a"],"published":"2015-04-08","related":[{"cvss_score":7.8,"headline":"Privilege escalation in SIMATIC WinCC","id":"CVE-2023-30897","kev_date_added":null,"published":"2023-06-13"},{"cvss_score":6.8,"headline":"Auth bypass in n/a","id":"CVE-2015-2823","kev_date_added":null,"published":"2015-04-08"},{"cvss_score":6.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2013-4911","kev_date_added":null,"published":"2013-07-31"},{"cvss_score":5.8,"headline":"Open redirect in n/a","id":"CVE-2013-4912","kev_date_added":null,"published":"2013-07-31"},{"cvss_score":5.8,"headline":"Open redirect in n/a","id":"CVE-2012-3003","kev_date_added":null,"published":"2012-06-08"},{"cvss_score":5.5,"headline":"Code injection in n/a","id":"CVE-2012-2596","kev_date_added":null,"published":"2012-06-08"},{"cvss_score":5,"headline":"Weak cryptography in n/a","id":"CVE-2015-1358","kev_date_added":null,"published":"2015-02-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Man-in-the-middle attackers can cause denial of service on Siemens SIMATIC HMI panels via crafted packets on TCP port 102.","url":"https://insights.sbomify.com/CVE-2015-2822/"}