CVE-2015-2884 Information disclosure in Philips In.Sight B120/37
Remote attackers can obtain sensitive information from Philips In.Sight cameras by accessing specific URLs and URIs directly.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2015-2884?
CVE-2015-2884 is a high-severity vulnerability in Philips In.Sight B120/37, published on 10 Apr 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.
Official description
Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
Weakness: CWE-200
Which versions are affected by CVE-2015-2884?
It affects 1 product.
Products include Philips In.sight B120\\37.
How do I fix CVE-2015-2884?
No fix has been published for CVE-2015-2884 yet. Limit exposure of the affected software until one is available.
Is CVE-2015-2884 being exploited?
There is no known exploitation of CVE-2015-2884 in the wild and no public exploit code.
Other vulnerabilities in Philips In.Sight B120/37
Sources
Also known as GHSA-chr6-vh2q-h38g.