{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2015-3955 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2015-3955 yet. Limit exposure of the affected software until one is available.","what":"CVE-2015-3955 is a critical memory corruption vulnerability in n/a, published on 6 Jul 2015. It can be exploited over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2015-3955 and fix it if it is affected.\n\nWhat it is: CVE-2015-3955 is a critical memory corruption vulnerability in n/a, published on 6 Jul 2015. It can be exploited over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2015-3955 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2015-3955/ (Markdown: https://insights.sbomify.com/CVE-2015-3955/index.md)","id":"CVE-2015-3955","markdown":"https://insights.sbomify.com/CVE-2015-3955/index.md","name":"CVE-2015-3955","record":{"aliases":["GHSA-cmhg-mjpq-282r"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Infusion pump","requires_auth":"unknown","summary":"Remote attackers can execute arbitrary code on Hospira LifeCare PCA Infusion Systems via a stack-based buffer overflow.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"lifecare_pcainfusion_firmware","vendor":"hospira"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"Stack-based buffer overflow in Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to execute arbitrary code via unspecified vectors.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2015-3955","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2015"},"n_packages":0,"n_references":3,"next":{"headline":"Missing authorization in Plum A+ Infusion System","id":"CVE-2015-3956"},"packages":[],"prev":{"headline":"Auth bypass in Plum A+ Infusion System","id":"CVE-2015-3954"},"products":["n/a"],"published":"2015-07-06","related":[{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2015-3958","kev_date_added":null,"published":"2015-07-06"},{"cvss_score":7.6,"headline":"Hospira LifeCare PCA Infusion System","id":"CVE-2014-5406","kev_date_added":null,"published":"2015-07-06"},{"cvss_score":5,"headline":"Hardcoded credentials in n/a","id":"CVE-2015-1011","kev_date_added":null,"published":"2015-07-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Remote attackers can execute arbitrary code on Hospira LifeCare PCA Infusion Systems via a stack-based buffer overflow.","url":"https://insights.sbomify.com/CVE-2015-3955/"}