{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2015-3956 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2015-3956 yet. Limit exposure of the affected software until one is available.","what":"CVE-2015-3956 is a critical missing authorization vulnerability in Hospira Plum A+ Infusion System, published on 25 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2015-3956 and fix it if it is affected.\n\nWhat it is: CVE-2015-3956 is a critical missing authorization vulnerability in Hospira Plum A+ Infusion System, published on 25 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2015-3956 in the wild and no public exploit code.\n\nAffected product: Hospira Plum A+ Infusion System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2015-3956/ (Markdown: https://insights.sbomify.com/CVE-2015-3956/index.md)","id":"CVE-2015-3956","markdown":"https://insights.sbomify.com/CVE-2015-3956/index.md","name":"CVE-2015-3956","record":{"aliases":["GHSA-2vhp-v3rh-j2qr"],"analysis":{"component_type":"ics_ot","fix_type":"configuration_change","impacts":["data_modify","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Infusion pump system","requires_auth":"none","summary":"Unauthenticated attackers on the network can modify drug libraries, firmware, and pump configurations on vulnerable Hospira infusion systems.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"plum_a\\+3_infusion_system_firmware","vendor":"pifzer"},{"product":"plum_a\\+_infusion_system_firmware","vendor":"pifzer"},{"product":"symbiq_infusion_system_firmware","vendor":"pifzer"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"}],"description":"Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior accept drug libraries, firmware updates, pump commands, and unauthorized configuration changes from unauthenticated devices on the host network. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Plum A+ Infusion System","id":"CVE-2015-3956","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2015"},"n_packages":0,"n_references":1,"next":{"headline":"Hardcoded credentials in n/a","id":"CVE-2015-3957"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2015-3955"},"products":["Plum A+ Infusion System","Plum A+3 Infusion System","Symbiq Infusion System"],"published":"2019-03-25","related":[{"cvss_score":9.8,"headline":"Hardcoded credentials in Plum A+ Infusion System","id":"CVE-2015-3953","kev_date_added":null,"published":"2019-03-25"},{"cvss_score":9.8,"headline":"Auth bypass in Plum A+ Infusion System","id":"CVE-2015-3954","kev_date_added":null,"published":"2019-03-25"},{"cvss_score":7.5,"headline":"Information disclosure in Plum A+ Infusion System","id":"CVE-2015-3952","kev_date_added":null,"published":"2019-03-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["Hospira"]},"summary":"Unauthenticated attackers on the network can modify drug libraries, firmware, and pump configurations on vulnerable Hospira infusion systems.","url":"https://insights.sbomify.com/CVE-2015-3956/"}