{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2015-3972 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2015-3972 yet. Limit exposure of the affected software until one is available.","what":"CVE-2015-3972 is a critical vulnerability in n/a, published on 28 Oct 2015. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2015-3972 and fix it if it is affected.\n\nWhat it is: CVE-2015-3972 is a critical vulnerability in n/a, published on 28 Oct 2015. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2015-3972 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2015-3972/ (Markdown: https://insights.sbomify.com/CVE-2015-3972/index.md)","id":"CVE-2015-3972","markdown":"https://insights.sbomify.com/CVE-2015-3972/index.md","name":"CVE-2015-3972","record":{"aliases":["GHSA-fmpv-vgf3-9w39"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Janitza power meter","requires_auth":"none","summary":"Remote attackers can brute-force short PINs to gain unauthorized access to Janitza UMG power meter web interfaces.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"umg_508","vendor":"janitza"},{"product":"umg_509","vendor":"janitza"},{"product":"umg_511","vendor":"janitza"},{"product":"umg_604","vendor":"janitza"},{"product":"umg_605","vendor":"janitza"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"cwes":[{"id":"CWE-254","name":null}],"description":"The web interface on Janitza UMG 508, 509, 511, 604, and 605 devices supports only short PIN values for authentication, which makes it easier for remote attackers to obtain access via a brute-force attack.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in n/a","id":"CVE-2015-3972","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2015"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in n/a","id":"CVE-2015-3973"},"packages":[],"prev":{"headline":"Missing authorization in n/a","id":"CVE-2015-3971"},"products":["n/a"],"published":"2015-10-28","related":[{"cvss_score":7.5,"headline":"Hardcoded credentials in n/a","id":"CVE-2015-3968","kev_date_added":null,"published":"2015-10-28"},{"cvss_score":7.5,"headline":"Missing authorization in n/a","id":"CVE-2015-3971","kev_date_added":null,"published":"2015-10-28"},{"cvss_score":6.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2015-3967","kev_date_added":null,"published":"2015-10-28"},{"cvss_score":5,"headline":"Information disclosure in n/a","id":"CVE-2015-3969","kev_date_added":null,"published":"2015-10-28"},{"cvss_score":5,"headline":"Information disclosure in n/a","id":"CVE-2015-3973","kev_date_added":null,"published":"2015-10-28"},{"cvss_score":4.3,"headline":"Cross-site scripting in n/a","id":"CVE-2015-3970","kev_date_added":null,"published":"2015-10-28"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Remote attackers can brute-force short PINs to gain unauthorized access to Janitza UMG power meter web interfaces.","url":"https://insights.sbomify.com/CVE-2015-3972/"}