CVE-2016-11022 Command injection in n/a

High 7.2 Published Updated

Remote attackers can execute arbitrary code with root privileges on NETGEAR Prosafe wireless controllers via shell metacharacters in the login handler.

Exploited in the wild
Not known
Login needed
An administrator
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2016-11022?

CVE-2016-11022 is a high-severity command injection vulnerability in n/a, published on 23 Mar 2020. An attacker needs administrator access to exploit it, with no action from the victim.

Official description

NETGEAR Prosafe WC9500 5.1.0.17, WC7600 5.1.0.17, and WC7520 2.5.0.35 devices allow a remote attacker to execute code with root privileges via shell metacharacters in the reqMethod parameter to login_handler.php.

Weakness: CWE-78

Which versions are affected by CVE-2016-11022?

It affects 3 products.

Products include Netgear Prosafe Wc7520 Firmware, Netgear Prosafe Wc7600 Firmware, Netgear Prosafe Wc9500 Firmware.

How do I fix CVE-2016-11022?

No fix has been published for CVE-2016-11022 yet. Limit exposure of the affected software until one is available.

Upgrade, and pass arguments to programs as a list instead of through a shell. More about Command injection.

Is CVE-2016-11022 being exploited?

There is no known exploitation of CVE-2016-11022 in the wild and no public exploit code.

Sources

Also known as GHSA-hgc7-5rw6-5h4m.

Is CVE-2016-11022 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free