{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2016-4785 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2016-4785 yet. Limit exposure of the affected software until one is available.","what":"CVE-2016-4785 is a medium-severity vulnerability in n/a, published on 31 May 2016. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2016-4785 and fix it if it is affected.\n\nWhat it is: CVE-2016-4785 is a medium-severity vulnerability in n/a, published on 31 May 2016. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2016-4785 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2016-4785/ (Markdown: https://insights.sbomify.com/CVE-2016-4785/index.md)","id":"CVE-2016-4785","markdown":"https://insights.sbomify.com/CVE-2016-4785/index.md","name":"CVE-2016-4785","record":{"aliases":["GHSA-q5g2-gj2v-rv2v"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SIPROTEC Ethernet module","requires_auth":"none","summary":"Remote attackers with network access can read limited device memory via the integrated web server on affected SIPROTEC Ethernet modules.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"siprotec_firmware","vendor":"siemens"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2016-4785","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2016"},"n_packages":0,"n_references":6,"next":{"headline":"Denial of service in n/a","id":"CVE-2016-4786"},"packages":[],"prev":{"headline":"Information disclosure in n/a","id":"CVE-2016-4784"},"products":["n/a"],"published":"2016-05-31","related":[{"cvss_score":7.8,"headline":"Denial of service in n/a","id":"CVE-2015-5374","kev_date_added":null,"published":"2015-07-18"},{"cvss_score":5.3,"headline":"Information disclosure in n/a","id":"CVE-2016-4784","kev_date_added":null,"published":"2016-05-31"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["n/a"]},"summary":"Remote attackers with network access can read limited device memory via the integrated web server on affected SIPROTEC Ethernet modules.","url":"https://insights.sbomify.com/CVE-2016-4785/"}