{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2016-5809 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2016-5809 yet. Limit exposure of the affected software until one is available.","what":"CVE-2016-5809 is a high-severity vulnerability in Schneider Electric IONXXXX Series, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2016-5809 and fix it if it is affected.\n\nWhat it is: CVE-2016-5809 is a high-severity vulnerability in Schneider Electric IONXXXX Series, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2016-5809 in the wild and no public exploit code.\n\nAffected product: Schneider Electric IONXXXX Series. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2016-5809/ (Markdown: https://insights.sbomify.com/CVE-2016-5809/index.md)","id":"CVE-2016-5809","markdown":"https://insights.sbomify.com/CVE-2016-5809/index.md","name":"CVE-2016-5809","record":{"aliases":["GHSA-rrvq-67jw-2vxq"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Schneider Electric power meter","requires_auth":"none","summary":"Attackers can perform unauthorized configuration changes on Schneider Electric power meters due to missing CSRF tokens.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ion5000","vendor":"schneider-electric"},{"product":"ion7300","vendor":"schneider-electric"},{"product":"ion7500","vendor":"schneider-electric"},{"product":"ion7600","vendor":"schneider-electric"},{"product":"ion8650","vendor":"schneider-electric"},{"product":"ion8800","vendor":"schneider-electric"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2018-05-17","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2018-05-17","kind":"exploitdb","ref":"44640","stars":null,"title":"Powerlogic/Schneider Electric IONXXXX Series - Cross-Site Request Forgery"}],"tier":"poc_unverified"},"has_fix":null,"headline":"Cross-site request forgery in Schneider Electric IONXXXX Series","id":"CVE-2016-5809","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2016"},"n_packages":0,"n_references":3,"next":{"headline":"Information disclosure in n/a","id":"CVE-2016-5810"},"packages":[],"prev":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2016-5808"},"products":["Schneider Electric IONXXXX Series"],"published":"2017-02-13","related":[{"cvss_score":9.8,"headline":"Missing authorization in Schneider Electric IONXXXX Series Power Meter Vulnerabilities","id":"CVE-2016-5815","kev_date_added":null,"published":"2017-02-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Attackers can perform unauthorized configuration changes on Schneider Electric power meters due to missing CSRF tokens.","url":"https://insights.sbomify.com/CVE-2016-5809/"}