{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2016-5815 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2016-5815 yet. Limit exposure of the affected software until one is available.","what":"CVE-2016-5815 is a critical missing authorization vulnerability in Schneider Electric IONXXXX Series Power Meter Vulnerabilities, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2016-5815 and fix it if it is affected.\n\nWhat it is: CVE-2016-5815 is a critical missing authorization vulnerability in Schneider Electric IONXXXX Series Power Meter Vulnerabilities, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2016-5815 in the wild and no public exploit code.\n\nAffected product: Schneider Electric IONXXXX Series Power Meter Vulnerabilities. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2016-5815/ (Markdown: https://insights.sbomify.com/CVE-2016-5815/index.md)","id":"CVE-2016-5815","markdown":"https://insights.sbomify.com/CVE-2016-5815/index.md","name":"CVE-2016-5815","record":{"aliases":["GHSA-mfpm-xw3v-wfrj"],"analysis":{"component_type":"ics_ot","fix_type":"configuration_change","impacts":["data_modify","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Schneider Electric power meter","requires_auth":"none","summary":"Unauthorized users can access the management portal and modify configurations because authentication is disabled by default on Schneider Electric power meters.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ion5000","vendor":"schneider-electric"},{"product":"ion7300","vendor":"schneider-electric"},{"product":"ion7500","vendor":"schneider-electric"},{"product":"ion7600","vendor":"schneider-electric"},{"product":"ion8650","vendor":"schneider-electric"},{"product":"ion8800","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Schneider Electric IONXXXX Series Power Meter Vulnerabilities","id":"CVE-2016-5815","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2016"},"n_packages":0,"n_references":2,"next":{"headline":"Hardcoded credentials in n/a","id":"CVE-2016-5816"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2016-5814"},"products":["Schneider Electric IONXXXX Series Power Meter Vulnerabilities"],"published":"2017-02-13","related":[{"cvss_score":8.8,"headline":"Cross-site request forgery in Schneider Electric IONXXXX Series","id":"CVE-2016-5809","kev_date_added":null,"published":"2017-02-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Unauthorized users can access the management portal and modify configurations because authentication is disabled by default on Schneider Electric power meters.","url":"https://insights.sbomify.com/CVE-2016-5815/"}