{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2016-7856 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2016-7856 yet. Limit exposure of the affected software until one is available.","what":"CVE-2016-7856 is a critical memory corruption vulnerability in Adobe DNG Converter 9.7 and earlier, published on 15 Dec 2016. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2016-7856 and fix it if it is affected.\n\nWhat it is: CVE-2016-7856 is a critical memory corruption vulnerability in Adobe DNG Converter 9.7 and earlier, published on 15 Dec 2016. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2016-7856 in the wild and no public exploit code.\n\nAffected product: Adobe DNG Converter 9.7 and earlier. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2016-7856/ (Markdown: https://insights.sbomify.com/CVE-2016-7856/index.md)","id":"CVE-2016-7856","markdown":"https://insights.sbomify.com/CVE-2016-7856/index.md","name":"CVE-2016-7856","record":{"aliases":["GHSA-4r6g-pqff-6vpv"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Adobe DNG Converter","requires_auth":"none","summary":"An exploitable memory corruption vulnerability in Adobe DNG Converter allows attackers to execute arbitrary code.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"adobe","cpe":[{"product":"dng_converter","vendor":"adobe"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"Adobe DNG Converter versions 9.7 and earlier have an exploitable memory corruption vulnerability. Successful exploitation could lead to arbitrary code execution.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in Adobe DNG Converter 9.7 and earlier","id":"CVE-2016-7856","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2016"},"n_packages":0,"n_references":2,"next":{"headline":"Use after free in Adobe Flash Player 23.0.0.205 and earlier, 11.2.202.643 and earlier","id":"CVE-2016-7857"},"packages":[],"prev":{"headline":"Adobe Flash Player Use-After-Free","id":"CVE-2016-7855"},"products":["Adobe DNG Converter 9.7 and earlier"],"published":"2016-12-15","related":[{"cvss_score":9.8,"headline":"Memory corruption in Adobe DNG Converter 9.12.1 and earlier versions","id":"CVE-2017-11295","kev_date_added":null,"published":"2017-12-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"An exploitable memory corruption vulnerability in Adobe DNG Converter allows attackers to execute arbitrary code.","url":"https://insights.sbomify.com/CVE-2016-7856/"}