{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2016-8358 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2016-8358 yet. Limit exposure of the affected software until one is available.","what":"CVE-2016-8358 is a high-severity vulnerability in Smiths-Medical CADD-Solis Medication Safety Software through 3.1, published on 13 Feb 2017. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2016-8358 and fix it if it is affected.\n\nWhat it is: CVE-2016-8358 is a high-severity vulnerability in Smiths-Medical CADD-Solis Medication Safety Software through 3.1, published on 13 Feb 2017. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2016-8358 in the wild and no public exploit code.\n\nAffected product: Smiths-Medical CADD-Solis Medication Safety Software through 3.1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2016-8358/ (Markdown: https://insights.sbomify.com/CVE-2016-8358/index.md)","id":"CVE-2016-8358","markdown":"https://insights.sbomify.com/CVE-2016-8358/index.md","name":"CVE-2016-8358","record":{"aliases":["GHSA-6c6r-7283-r9ph"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical infusion pump software","requires_auth":"low_privilege","summary":"A man-in-the-middle attacker can intercept and manipulate communication between medical device endpoints due to lack of identity verification.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cadd-solis_medication_safety_software","vendor":"smiths-medical"}],"cvss":{"score":8.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-346","name":"Origin Validation Error"}],"description":"An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in Smiths-Medical CADD-Solis Medication Safety Software through 3.1","id":"CVE-2016-8358","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2016"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in Moxa ioLogik E1200 Series before 3.12","id":"CVE-2016-8359"},"packages":[],"prev":{"headline":"Missing authorization in Lynxspring JENEsys BAS Bridge 1.1.8 and older","id":"CVE-2016-8357"},"products":["Smiths-Medical CADD-Solis Medication Safety Software through 3.1"],"published":"2017-02-13","related":[{"cvss_score":9.9,"headline":"Privilege escalation in Smiths-Medical CADD-Solis Medication Safety Software through 3.1","id":"CVE-2016-8355","kev_date_added":null,"published":"2017-02-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"A man-in-the-middle attacker can intercept and manipulate communication between medical device endpoints due to lack of identity verification.","url":"https://insights.sbomify.com/CVE-2016-8358/"}