{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2016-9360 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2016-9360 yet. Limit exposure of the affected software until one is available.","what":"CVE-2016-9360 is a medium-severity vulnerability in GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian, published on 13 Feb 2017. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2016-9360 and fix it if it is affected.\n\nWhat it is: CVE-2016-9360 is a medium-severity vulnerability in GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian, published on 13 Feb 2017. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2016-9360 in the wild and no public exploit code.\n\nAffected product: GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2016-9360/ (Markdown: https://insights.sbomify.com/CVE-2016-9360/index.md)","id":"CVE-2016-9360","markdown":"https://insights.sbomify.com/CVE-2016-9360/index.md","name":"CVE-2016-9360","record":{"aliases":["GHSA-m2cq-36cr-qccv"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"GE Proficy SCADA","requires_auth":"high_privilege","summary":"An attacker with authenticated session access can retrieve user passwords in GE Proficy SCADA and Historian products.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cimplicity","vendor":"ge"},{"product":"historian","vendor":"ge"},{"product":"ifix","vendor":"ge"}],"cvss":{"score":6.7,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-522","name":"Insufficiently Protected Credentials"}],"description":"An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian","id":"CVE-2016-9360","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2016"},"n_packages":0,"n_references":3,"next":{"headline":"Auth bypass in Moxa NPort","id":"CVE-2016-9361"},"packages":[],"prev":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2016-9359"},"products":["GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian"],"published":"2017-02-13","related":[{"cvss_score":9.1,"headline":"XML external entity in GE Proficy Cimplicity GDS","id":"CVE-2018-15362","kev_date_added":null,"published":"2018-12-07"},{"cvss_score":7.8,"headline":"GE Digital CIMPLICITY Process Control","id":"CVE-2023-4487","kev_date_added":null,"published":"2023-09-05"},{"cvss_score":7.8,"headline":"GE CIMPLICITY Untrusted Pointer Dereference","id":"CVE-2022-2002","kev_date_added":null,"published":"2022-12-07"},{"cvss_score":7.8,"headline":"GE CIMPLICITY Heap-based Buffer Overflow","id":"CVE-2022-2948","kev_date_added":null,"published":"2022-12-07"},{"cvss_score":7.8,"headline":"GE CIMPLICITY Access of Uninitialized Pointer","id":"CVE-2022-2952","kev_date_added":null,"published":"2022-12-07"},{"cvss_score":7.8,"headline":"GE CIMPLICITY Access of Uninitialized Pointer","id":"CVE-2022-3084","kev_date_added":null,"published":"2022-12-07"},{"cvss_score":7.8,"headline":"GE CIMPLICITY Out-of-bounds Write","id":"CVE-2022-3092","kev_date_added":null,"published":"2022-12-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"An attacker with authenticated session access can retrieve user passwords in GE Proficy SCADA and Historian products.","url":"https://insights.sbomify.com/CVE-2016-9360/"}