{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2016-9362 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2016-9362 yet. Limit exposure of the affected software until one is available.","what":"CVE-2016-9362 is a critical authentication bypass vulnerability in WAGO Ethernet cards, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2016-9362 and fix it if it is affected.\n\nWhat it is: CVE-2016-9362 is a critical authentication bypass vulnerability in WAGO Ethernet cards, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2016-9362 in the wild and no public exploit code.\n\nAffected product: WAGO Ethernet cards. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2016-9362/ (Markdown: https://insights.sbomify.com/CVE-2016-9362/index.md)","id":"CVE-2016-9362","markdown":"https://insights.sbomify.com/CVE-2016-9362/index.md","name":"CVE-2016-9362","record":{"aliases":["GHSA-9grp-vp5p-rx5w"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"WAGO Ethernet cards","requires_auth":"none","summary":"Unauthenticated attackers can view and modify device settings by accessing a specific URL on WAGO Ethernet card web servers.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"750-xxxx_series_firmware","vendor":"wago"},{"product":"758-xxxx_series_firmware","vendor":"wago"},{"product":"pfc200_firmware","vendor":"wago"}],"cvss":{"score":9.1,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"An issue was discovered in WAGO 750-8202/PFC200 prior to FW04 (released August 2015), WAGO 750-881 prior to FW09 (released August 2016), and WAGO 0758-0874-0000-0111. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to edit and to view settings without authenticating.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in WAGO Ethernet cards","id":"CVE-2016-9362","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2016"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in Moxa NPort","id":"CVE-2016-9363"},"packages":[],"prev":{"headline":"Auth bypass in Moxa NPort","id":"CVE-2016-9361"},"products":["WAGO Ethernet cards"],"published":"2017-02-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-06","vendors":["n/a"]},"summary":"Unauthenticated attackers can view and modify device settings by accessing a specific URL on WAGO Ethernet card web servers.","url":"https://insights.sbomify.com/CVE-2016-9362/"}