{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-11508 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-11508 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-11508 is a high-severity SQL injection vulnerability in Tenable SecurityCenter, published on 2 Nov 2017. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-11508 and fix it if it is affected.\n\nWhat it is: CVE-2017-11508 is a high-severity SQL injection vulnerability in Tenable SecurityCenter, published on 2 Nov 2017. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-11508 in the wild and no public exploit code.\n\nAffected product: Tenable SecurityCenter. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-11508/ (Markdown: https://insights.sbomify.com/CVE-2017-11508/index.md)","id":"CVE-2017-11508","markdown":"https://insights.sbomify.com/CVE-2017-11508/index.md","name":"CVE-2017-11508","record":{"aliases":["GHSA-556h-vgqj-qrc3"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["data_read","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenable SecurityCenter","requires_auth":"low_privilege","summary":"An authenticated attacker can exploit SQL injection in diagnostic scans to gain unauthorized access to Tenable SecurityCenter.","user_interaction":"not_required","vuln_class":"sql_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"tenable","cpe":[{"product":"security_center","vendor":"tenable"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"}],"description":"SecurityCenter versions 5.5.0, 5.5.1 and 5.5.2 contain a SQL Injection vulnerability that could be exploited by an authenticated user with sufficient privileges to run diagnostic scans. An attacker could exploit this vulnerability by entering a crafted SQL query into the password field of a diagnostic scan within SecurityCenter. Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SQL injection in SecurityCenter","id":"CVE-2017-11508","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"sql_injection","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"SQL injection in Firebird SQL Server","id":"CVE-2017-11509"},"packages":[],"prev":{"headline":"Cross-site scripting in Check MK","id":"CVE-2017-11507"},"products":["SecurityCenter"],"published":"2017-11-02","related":[{"cvss_score":9.4,"headline":"Remote Code Execution","id":"CVE-2026-19626","kev_date_added":null,"published":"2026-08-14"},{"cvss_score":9.4,"headline":"Command Injection","id":"CVE-2026-19681","kev_date_added":null,"published":"2026-08-14"},{"cvss_score":9.4,"headline":"Command Injection","id":"CVE-2026-19682","kev_date_added":null,"published":"2026-08-14"},{"cvss_score":9.4,"headline":"SQL injection in Security Center","id":"CVE-2026-64877","kev_date_added":null,"published":"2026-07-21"},{"cvss_score":9.4,"headline":"Command Injection","id":"CVE-2026-64878","kev_date_added":null,"published":"2026-07-21"},{"cvss_score":9.4,"headline":"Command Injection","id":"CVE-2026-64879","kev_date_added":null,"published":"2026-07-21"},{"cvss_score":8.8,"headline":"Information disclosure in SecurityCenter","id":"CVE-2018-1154","kev_date_added":null,"published":"2018-08-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Tenable"]},"summary":"An authenticated attacker can exploit SQL injection in diagnostic scans to gain unauthorized access to Tenable SecurityCenter.","url":"https://insights.sbomify.com/CVE-2017-11508/"}