{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2017-12714 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-12714 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-12714 is a medium-severity denial of service vulnerability in Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI., published on 25 Apr 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-12714 and fix it if it is affected.\n\nWhat it is: CVE-2017-12714 is a medium-severity denial of service vulnerability in Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI., published on 25 Apr 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-12714 in the wild and no public exploit code.\n\nAffected product: Abbott Laboratories Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-12714/ (Markdown: https://insights.sbomify.com/CVE-2017-12714/index.md)","id":"CVE-2017-12714","markdown":"https://insights.sbomify.com/CVE-2017-12714/index.md","name":"CVE-2017-12714","record":{"aliases":["GHSA-4gwc-877g-8pxq"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Abbott pacemaker","requires_auth":"none","summary":"A nearby attacker can drain the battery of Abbott pacemakers by repeatedly sending RF wake-up commands, potentially causing device failure.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"accent_firmware","vendor":"abbott"},{"product":"accent_mri_firmware","vendor":"abbott"},{"product":"accent_st_firmware","vendor":"abbott"},{"product":"allure_firmware","vendor":"abbott"},{"product":"anthem_firmware","vendor":"abbott"},{"product":"assurity_firmware","vendor":"abbott"},{"product":"assurity_mri_firmware","vendor":"abbott"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-920","name":"Improper Restriction of Power Consumption"}],"description":"Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted \"RF wake-up\" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.","id":"CVE-2017-12714","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in Accent and Anthem","id":"CVE-2017-12716"},"packages":[],"prev":{"headline":"Missing authorization in Advantech WebAccess","id":"CVE-2017-12713"},"products":["Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI."],"published":"2018-04-25","related":[{"cvss_score":8.8,"headline":"Auth bypass in Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.","id":"CVE-2017-12712","kev_date_added":null,"published":"2018-04-25"},{"cvss_score":6.5,"headline":"Information disclosure in Accent and Anthem","id":"CVE-2017-12716","kev_date_added":null,"published":"2018-04-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Abbott Laboratories"]},"summary":"A nearby attacker can drain the battery of Abbott pacemakers by repeatedly sending RF wake-up commands, potentially causing device failure.","url":"https://insights.sbomify.com/CVE-2017-12714/"}