{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2017-12716 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-12716 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-12716 is a medium-severity vulnerability in Abbott Laboratories Accent and Anthem, published on 25 Apr 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-12716 and fix it if it is affected.\n\nWhat it is: CVE-2017-12716 is a medium-severity vulnerability in Abbott Laboratories Accent and Anthem, published on 25 Apr 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-12716 in the wild and no public exploit code.\n\nAffected product: Abbott Laboratories Accent and Anthem. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-12716/ (Markdown: https://insights.sbomify.com/CVE-2017-12716/index.md)","id":"CVE-2017-12716","markdown":"https://insights.sbomify.com/CVE-2017-12716/index.md","name":"CVE-2017-12716","record":{"aliases":["GHSA-x247-46rv-347w"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Abbott pacemaker","requires_auth":"none","summary":"Attackers can read unencrypted patient data transmitted via RF or stored on Abbott Accent and Anthem pacemakers, requiring a firmware update to mitigate.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"accent_firmware","vendor":"abbott"},{"product":"accent_mri_firmware","vendor":"abbott"},{"product":"accent_st_firmware","vendor":"abbott"},{"product":"anthem_firmware","vendor":"abbott"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"},{"id":"CWE-311","name":"Missing Encryption of Sensitive Data"}],"description":"Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in Accent and Anthem","id":"CVE-2017-12716","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Other in Advantech WebAccess","id":"CVE-2017-12717"},"packages":[],"prev":{"headline":"Denial of service in Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.","id":"CVE-2017-12714"},"products":["Accent and Anthem"],"published":"2018-04-25","related":[{"cvss_score":8.8,"headline":"Auth bypass in Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.","id":"CVE-2017-12712","kev_date_added":null,"published":"2018-04-25"},{"cvss_score":6.5,"headline":"Denial of service in Accent/Anthem, Accent MRI, Assurity/Allure, and Assurity MRI.","id":"CVE-2017-12714","kev_date_added":null,"published":"2018-04-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Abbott Laboratories"]},"summary":"Attackers can read unencrypted patient data transmitted via RF or stored on Abbott Accent and Anthem pacemakers, requiring a firmware update to mitigate.","url":"https://insights.sbomify.com/CVE-2017-12716/"}