{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-12718 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-12718 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-12718 is a high-severity memory corruption vulnerability in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, published on 15 Feb 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-12718 and fix it if it is affected.\n\nWhat it is: CVE-2017-12718 is a high-severity memory corruption vulnerability in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, published on 15 Feb 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-12718 in the wild and no public exploit code.\n\nAffected product: Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-12718/ (Markdown: https://insights.sbomify.com/CVE-2017-12718/index.md)","id":"CVE-2017-12718","markdown":"https://insights.sbomify.com/CVE-2017-12718/index.md","name":"CVE-2017-12718","record":{"aliases":["GHSA-84pw-5frw-ww2p"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical infusion pump","requires_auth":"none","summary":"A buffer overflow in a third-party component allows remote code execution on Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pumps.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"medfusion_4000_wireless_syringe_infusion_pump","vendor":"smiths-medical"}],"cvss":{"score":8.1,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"},{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2018-01-18","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2018-01-18","kind":"exploitdb","ref":"43776","stars":null,"title":"Smiths Medical Medfusion 4000 - 'DHCP' Denial of Service"}],"tier":"poc_unverified"},"has_fix":null,"headline":"Memory corruption in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump","id":"CVE-2017-12718","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2017"},"n_packages":0,"n_references":4,"next":{"headline":"Null dereference in Advantech WebAccess","id":"CVE-2017-12719"},"packages":[],"prev":{"headline":"Other in Advantech WebAccess","id":"CVE-2017-12717"},"products":["Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump"],"published":"2018-02-15","related":[{"cvss_score":8.1,"headline":"Missing authorization in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump","id":"CVE-2017-12720","kev_date_added":null,"published":"2018-02-15"},{"cvss_score":8.1,"headline":"Hardcoded credentials in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump","id":"CVE-2017-12724","kev_date_added":null,"published":"2018-02-15"},{"cvss_score":7.3,"headline":"Hardcoded credentials in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump","id":"CVE-2017-12726","kev_date_added":null,"published":"2018-02-15"},{"cvss_score":5.9,"headline":"Weak cryptography in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump","id":"CVE-2017-12721","kev_date_added":null,"published":"2018-02-15"},{"cvss_score":5.6,"headline":"Hardcoded credentials in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump","id":"CVE-2017-12725","kev_date_added":null,"published":"2018-02-15"},{"cvss_score":5.3,"headline":"Memory corruption in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump","id":"CVE-2017-12722","kev_date_added":null,"published":"2018-02-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"A buffer overflow in a third-party component allows remote code execution on Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pumps.","url":"https://insights.sbomify.com/CVE-2017-12718/"}